Loosen the counter-nut 2 and remove cap 1.
Extract the spring 3 and overturn the pipe,
making the oil escape.
Move the pumping unit and drain the
remaining oil. When the oil has been
drained completely, introduce the amount
of new oil described in chapter 1.
Bleed the pumping unit of air, making it
rise and fall until complete loading.
Introduce the spring and screw the cap 1
until it is completely inserted on the pump-
ing rod. Block the cap to the pumping
rod via the counter-nut 2.