User`s manual

Battery Check Card – Hour Meter
1. Verify that turning on the machine the battery check card has
the following starting sequence:
- Turning on of the LED which correspond to the set-up (red
LED = “0”).
- Turning on of all the LEDs (check of the lamps)
- Turning on of the LEDs depending on the charge of the
battery
2. Verify the hour meter functionality
To verify which is the set-up you simply need to turn on the
machine and check which is the first LED that turns on. Counting
the LEDs since the left side any LED correspond to a position and
the LED which turn on correspond to the current set-up.
Verify that if the machine uses wet cell batteries the adjustment
is on position 1.
Verify that if the machine uses GEL batteries the adjustment is on
position 4.
WARNING: A wrong set-up of the battery control card can
compromise the battery efficiency and damage then in
irreversible way.
Hydraulic plant inspections
1. Fill up the solution tank and verify the sealing of the gasket
particularly on the solution valve and on the drain plug.
2. Verify that the water distribution on the floor is even and
dependent on the solution valve adjustment.
3. Check the internal cleanness of the water valve. If necessary
clean it using a metal bar putted inside the threaded hole of
the filter plug.
4. Verify the cleanness and functionality of the solution filter
under the solution tank plug.