User`s manual
MACHINE PREPARATION
3. BATTERY INSTALLATION
The machine will be supplied with a battery charger and either two 12V Wet or AGM
batteries.
The batteries must be housed in the battery tray in the battery compartment beneath
the recovery tank.
To insert the batteries you must:
1. Lower the squeegee and base
2. Open the rear hinge that secures the tank
3. Rotate the recovery tank as far as it will go, using the side handle
WARNING: To avoid acid spillage you can use sealed batteries.
WARNING: Perform one battery charging cycle before using the
machine.
4. TYPE OF BATTERY
To power the machine you can use:
• Wet batteries
• AGM batteries
• Gel batteries
OTHER TYPES MUST NOT BE USED.
The maximum dimensions and the weight are:
Width 6.7 in (171mm)
Length 12.9 in (329mm)
Height 9.6 in (245mm)
Weight 68 lb (31kg)
WARNING: Your charger must be set according to the type of
battery you install. Call BETCO customer service to ensure
correct charger setting after replacement batteries are installed.
The batteries must be handled using lifting and transportation means suitable for the
weight and dimensions.
They must be lifted by the handles on the upper part.
They must be connected together in series, to obtain an overall voltage of 24V on the lugs.
The electrical connection operations must be carried out by certified trained personnel.
2