User`s manual

MACHINE PREPARATION
5. BATTERY MAINTENANCE
For maintenance and recharging, follow the instructions provided by the battery
manufacturer.
6. BATTERY DISPOSAL
When the battery reaches the end of its working life, it must be disconnected by
certified professional, then lifted (using the handles and suitable lifting device) to
remove it from the battery compartment.
DEAD BATTERIES ARE CLASSIFIED AS HAZARDOUS WASTE AND MUST BE
DISPOSED OF AT AUTHORIZED BATTERY DISPOSAL COMPANY.
7. CONNECTING THE BATTERY CHARGER
Beneath the recovery tank there is the battery connector (2), the battery charger
connector must be plugged into. Disconnect the battery plug and plug the charger into
the machine plug.
WARNING: This process must be carried out by qualified
personnel. The incorrect or imperfect connection of the cables to
the connector can seriously harm people and damage objects.
2
8. RECHARGING THE BATTERIES
Perform one complete battery charge cycle before using the machine.
A
void totally discharging the battery! This can cause permanent damage to it.
Recharge as soon as the battery discharged signal light starts to flash.
WARNING: Never leave the batteries completely discharged, not
even if the machine is not being used. This can cause permanent
damage to them. While recharging, keep the recovery tank raised,
supporting it with the prop as shown in the figure. Ensure the
battery charger is suitable for the batteries installed, in terms of
capacity and type.
Danger of inhalation of gas and leakage of corrosive liquids.
Danger of fire: do not go near flames.