Operating Guide

21
inside the sauna. Then go to the control panel and press the power button. If the heat emitters now
heat, then the temperature sensor was the cause of the problem. You may have to wait about five
minutes to confirm if the heat emitters are generating heat. Remove the original temperature
sensor from its hole and replace it with the spare one.
Solution: Check the wiring harnesses coming from the power supply located on the roof of the sauna.
Make sure the wiring harness labeled “CTRL” is connected to the power supply at one end and
connected to another wiring harness labeled “CTRL” at the other end. If this wiring harness is not
properly connected, then the sauna will show signs of having no power.
4. CD Player Will Not Work
Solution: Check to make sure the lock screws on top of the radio have been removed. The CD player
will not work if the screws are not removed.