Specifications

2-WIRE 
FIRE SLC  
ADDRESSABLE 
LOOP 
4 OR 7 AMP MAIN 
POWER SUPPLY 
(GEMC-PS24V7A-R or 
GEMC-PS24V4A-R)
ADDRESSABLE 
SMOKE 
DETECTOR
FWC-FSLC-SMK
FWC-FSLC-HEAT
ADDRESSABLE  
HEAT 
DETECTOR 
FWC-FSLC-PULL 
ADDRESSABLE  
PULL STATION
(Also in Key Reset and Dual Action, 
Hex and Keyed models.)
FWC-FSLC-EZM2 
DUAL INPUT  
MONITOR MODULE 
FWC-FSLC-DUCT 
DUCT DETECTOR 
(Also available, 
Remote Annunciator Plate.)
F
I
R
E
W
O
L
F
UP TO 126 
DEVICES 
SMOKE DETECTOR
GEMC-WL-SMK
GEMC-WL-HEAT
HEAT DETECTOR
SINGLE ZONE 
TRANSMITTER  
WITH TAMPER 
GEMC-WL-WD2 
Single Fire 
initiating 
N/O device 
GEMC-NAC7 
NAC EXTENDER 
 (5, MAX.)
GEMC-F8ZCPIM  
8 Fire Zone Expander  
} 
8 ZONES OF  
CONVENTIONAL 2-WIRE SMOKES  
PULL STATIONS AND/OR HEAT DETECTORS
HORN 
STROBE 
MUST BE 
ALL 
WHEELOCK 
OR ALL 
SYSTEM 
SENSOR 
EOLR 
2.2K 
STROBE 
HORN 
HORN 
STROBE 
EOLR 
2.2K 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
} 
• 4 ON-BOARD NAC  
CIRCUITS (CLASS B) 
(NOT SHOWN)  
-- or -- 
• 2 ON-BOARD NAC  
CIRCUITS (CLASS A) 
EOLR 
2.2K
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
EOLR 
2.2K 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
S 
+ 
+ 
– 
– 
SMOKE 
2-WIRE 
FIRE BUS DEVICES 
GEMC-EZM8 
8 ZONE 
CONVENTIONAL 
ZONE EXPANSION 
MODULE 
GEMC-OUT8 
8 ZONE OUTPUT 
REMOTE RELAY 
MODULE 
GEMC-FPRINT 
PRINTER  
MODULE 
HORN 
STROBE 
MUST BE 
ALL 
WHEELOCK 
OR ALL 
SYSTEM 
SENSOR 
EOLR 
2.2K 
STROBE 
HORN 
HORN 
STROBE 
EOLR 
2.2K 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
FWC-FSLC-EZM1 
FAST RESPONSE 
MONITOR MODULE 
FWC-FSLC-RM2 
DUAL RELAY 
MODULE 
FWC-FSLC-SOM1 
SUPERVISED 
OUTPUT MODULE 
FWC-FSLC-CZM 
CONVENTIONAL 
ZONE MODULE 
FWC-FSLC-ISO 
SHORT CIRCUIT 
ISOLATOR 
FWC-FSLC-SMK6B 
(6" BASE ONLY) 
FIRE KEYPAD 
GEMC-FK1 
 (4, MAX.)
EOLR 
2.2K 
HORN 
EOLR 
2.2K 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
HORN 
STROBE 
EOLR 
2.2K 
HORN 
EOLR 
2.2K 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
STROBE 
HORN 
HORN 
STROBE 
} 
• 4 ON-BOARD NAC  
CIRCUITS (CLASS B) (SHOWN)  
-- or -- 
• 2 ON-BOARD NAC  
CIRCUITS (CLASS A) 
MUST BE ALL 
WHEELOCK OR ALL 
SYSTEM SENSOR 
INTERNET REPORTING
MODULE
FI
R
E
K
E
Y
P
A
D
G
E
M
C
-FK
1
GEMC-12V2APS-CF 
12V AUX POWER  
SUPPLY 
FW
C
-
F
S
L
C
-D
U
C
T
D
U
C
T
D
E
T
E
C
T
O
R
(
Also available,
tA it Pl
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
F
I
I
I
F
F
F
F
R
R
FF
E
R
R
W
W
W
W
W
W
W
W
W
W
W
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
L
L
L
L
L
L
L
L
L
L
L
O
O
O
O
O
O
O
O
O
O
O
O
O
O
F
F
F
F
F
F
F
F
F
F
F
F
F
F
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
W
C
-
FS
L
C
-P
U
AD
D
R
ES
S
A
B
L
E
F
W
C
-
F
S
L
C
-C
Z
M
C
O
NV
E
N
T
I
O
N
A
L
Z
O
N
E
M
O
D
U
L
E
FW
C
-
F
S
L
C
-S
O
M
S
U
P
E
R
V
I
S
E
D
O
U
T
P
U
T
M
O
D
U
L
E
F
W
C
-
F
S
L
C
-
R
M
2
D
U
A
L
R
E
L
A
Y
A
A
M
O
D
U
L
E
F
W
C
-F
S
L
C
-
I
SO
S
H
O
R
T
C
I
R
C
U
I
T
I
S
O
L
A
T
A
A
O
R
F
W
C
-
F
S
L
C
-
EZM
D
U
AL
I
N
P
U
T
M
O
N
I
T
O
R
M
O
D
U
L
E
W
C
-
F
S
L
C
-
H
E
A
A
D
D
R
E
S
S
A
B
L
E
H
E
A
T
T
A
D
D
R
E
S
S
A
B
L
E
S
M
O
K
E
E
W
C-
F
S
L
C
-
S
M
K
N
GEMC-RM3008  
OUTPUT 
MODULE 
8
L
O
N
SM
R
G
E
M
C
-
W
L
-
H
E
A
T
H
E
A
T
DE
T
E
C
T
O
R
G
WD
2
G
E
M
C
-
W
L
-
S
M
K
MO
KE
DE
T
E
C
T
O
R
G
E
M
C
W
L
H
E
A
T
SI
N
G
L
E
Z
O
S
i
ng
i
n
i
N
/
O
G
E
M
C
-
W
L
-
W
(
4MA
X)
GEMC-RECV 
WIRELESS 
RECEIVER 
GEMINI C-SERIES 
MOTHERBOARD 
2-WIRE 
BURG SLC 
ADDRESSABLE 
LOOP 
GEMINI C-SERIES COMMERCIAL  
COMBINATION CONTROL PANEL 
UP TO 126 
DEVICES 
DUAL TECH PIR 
GEMC-BSLC-DT 
SINGLE RELAY 
MODULE 
GEMC-BSLC-RLY 
GEMC-BM or 
GEMC-BM/PS 
BURGLARY 
MODULE 
PIR 
GEMC-WL-PIR 
DUAL TECH PIR 
GEMC-WL-DT 
GLASS BREAK 
GEMC-WL-GB 
GEMC-WL-WD2* 
WINDOW / DOOR 
TRANSMITTER 
WITH TAMPER 
KEYFOB 
GEM-KEYF 
BURGLARY BUS DEVICES 
GEMC-RECV 
WIRELESS 
RECEIVER 
SINGLE POINT 
CONVENTIONAL 
ZONE  
EXPANDER 
GEMC-BSLC-1PT 
GEMC-BSLC-4PT 
4 POINT  
CONVENTIONAL 
ZONE 
EXPANDER 
 (4, MAX.)
BURGLARY 
KEYPAD 
 (15, MAX.)
GEMC-BK1 
PIR 
GEMC-BSLC-PIR 
GEM-ACM1D  
ACCESS  
CONTROL  
MODULE 
 (4, MAX.)
GEM-2D 
SECOND DOOR  
ACCESS CONTROL 
ACCESSORY  
ACCESS   
CONTROL   
DEVICES
(ONE FOR EACH  
GEM-ACM1D) 
GEMC-WL-WD 
LOW PROFILE 
WINDOW / DOOR 
TRANSMITTER 
GEMC-EZM8 
8 ZONE  
CONVENTIONAL 
ZONE EXPANSION 
MODULE 
 (31, MAX.)
GEMC-OUT8 
8 ZONE OUTPUT 
REMOTE RELAY 
MODULE 
 (11, MAX.)
GEMC-RM3008  
OUTPUT  
MODULE 
 (11, MAX.)
†Residential Burglary when both loops are used
Single Commercial Burglary Supervised Loop and Integral Magnetic Contact  
2 SLC MODULES, max. 
• Two Fire or 
• Two Burglary or 
• One Fire and one Burglary 
Note: The four GEMC-RECV max. is reduced by 1 for each SLC module. 
GEMC-RS232 
SERIAL OUTPUT 
CONVERTER
GEMC-12V2APS-R 
12V AUX POWER  
SUPPLY 
B
U
R
G
L
A
R
Y
R
R
GEMC-BSLC Burg SLC Mod. and 
GEMC-FW-SLC Fire SCL Mod
Mount beneath motherboard
Configuration Diagram
5