INSTALLATION AND OPERATING INSTRUCTIONS for all Hydrocarbon CT Cross Temp™ Freezer / Refrigerator Models 809-154A REV B 10/28/2020 3779 CHAMPION BLVD, WINSTON-SALEM, NC 27105 Phone: (888) 845-9800 | Fax: (800) 253-5168 | Web: beverage-air.
User Manual for CT Freezer / Refrigerator Beverage-Air WELCOME Congratulations on your purchase of Beverage-Air food service equipment. Every employee welcomes you to the family of satisfied Beverage-Air customers. From the earliest stages of production design, to focused steps in fabrication and assembly, rigid standards of quality are maintained by our staff of skilled employees.
User Manual for CT Freezer / Refrigerator Beverage-Air SAFETY This appliance has been designed with your safety in mind. It has many features to keep you from being harmed. However, safe operation and maintenance are your responsibilities. CAUTION Use: When using this unit, please: • Move it carefully. If on casters be sure the casters do NOT run over the power cord. • Lock the casters when in use. • Seek help.
User Manual for CT Freezer / Refrigerator Beverage-Air SAFETY CAUTION CAUTION: If it is necessary to move the Refrigerator after removal from the skid, remove all doors and carefully push the unit at a point of no more than 36” from the bottom to avoid damage. Do NOT push in this area. Height will vary by model Push ONLY below the 36 inch / .91 meter height 4 Beverage-Air Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air IMPORTANT INFORMATION This unit is intended to be used in a commercial application. That includes bars and restaurants. The manufacturer has designed and produced this machine with the finest in materials. The manufacturer assumes no liability for units that have been altered in any way. Alterations or part substitutions will void the warranty. If installed in a residence some commercial service companies may not be able to service it on site.
User Manual for CT Freezer / Refrigerator Beverage-Air PRODUCT INFORMATION Cabinet Dimensions w x d x h (Inches) Half or Full Door Glass or Solid Door Full Load Amps Power Cord Plug (NEMA) Refrigerant Type / Charge (g) CT1HC-1G 26 x 33 5/8 x 84 1/2 Full Glass 8 5-15P R-290 / 140* CT1HC-1HG 26 x 33 5/8 x 84 1/2 Half Glass 8 5-15P R-290 / 140* CT1HC-1HS 26 x 33 5/8 x 85 Half Solid 8 5-15P R-290 / 140* CT1HC-1S 26 x 33 5/8 x 85 Full Solid 8 5-15P R-290 / 140* 26 5/8 x 34 5/8
User Manual for CT Freezer / Refrigerator Beverage-Air CLEARANCE AND PLACEMENT 12" AT TOP 0" AT BACK 6" AT BOTTOM 0" AT SIDES CT12-12HC-1HC Spacing Placement Consider the following when selecting a location for your Refrigerator: Clearance: CT12-12HC-1HS Clearance • 12 in. at the top • 12 in. at the top • 3.0 in. at the rear, • 0.0 in. at the rear, • 0.0 in. at the left side • 0.0 in. at the left side • 0.0 in. at the right side • 0.0 in. at the right side • 0.
User Manual for CT Freezer / Refrigerator Beverage-Air UNPACKING AND SET UP Carefully inspect the shipping carton for damage. This is the only time that shipping damage may be claimed. If damage is suspected, open the carton immediately and, if there is damage, retain the carton and contact the shipper to make a claim. Do NOT contact the manufacturer. Uncrating Tools Needed: ¾” box wrench, adjustable wrench, level, flat head screw driver, and box cutter.
User Manual for CT Freezer / Refrigerator Beverage-Air VAPORIZER PAN INSTALLATION Tools Needed Impact Gun with a Philips head bit OR A Philips head screwdriver Parts Included VAPORIZER ASSY 1D DT, BOTTOM Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air MOUNTING SCREWS 1. 2. 1. From the back of the cabinet, find the (4x) Philips head screws on the bottom. 2. Using a tool with a Philips head tip, back the screws out about a ¼”. BEFORE STARTING MAKE SURE THE COOLER IS UNPLUGGED 10 Beverage-Air Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air SECURING THE PAN ASSEMBLY 1. 2. 1. Using the slots on the pan bracket, slide the assembly onto the screws then tighten the screws. 2. NOTE: Once the pan is secured, make sure both hoses are inside the pan The hoses are often shipped with extra length and will need trimmed. Make sure the hose is not touching the heating element. Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air ENERGIZING THE VAPORIZER 1. 2. 12 1. Locate the receptacle at the bottom of the back channel 2. Plug the vaporizer cord into the receptacle. 3. - the cord from hanging on the ground. If the cord is too long, use a zip tie to keep Beverage-Air Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air SHELF INSTALLATION 1. Determine the proper location for the shelf clips. The reference numbers on the pilaster can serve as a guide to ensure all clips are properly located. 2. Insert the top tab of the shelf clip into the desired hole of the pilaster. The retaining tab MUST be facing up as shown. 3. Rotate the clip downwards and insert the bottom tab into the matching hole in the pilaster.
User Manual for CT Freezer / Refrigerator Beverage-Air ELECTRICAL This is a cord-connected unit, and must be connected to its own dedicated power supply. Check the dataplate on the machine to confirm the voltage and per the dataplate use the correct fuses or HACR circuit breakers. Note: Do not connect to GFI / GFCI outlets. Connection to that type of outlet can result in product loss due to unsafe cabinet temperature when GFI device trips from moisture.
User Manual for CT Freezer / Refrigerator Beverage-Air USING THE UNIT Operation is simple, just keep it connected to the correct power supply and the Cross Temp™ freezer/refrigerator will maintain the internal temperature it has been set to. Keep the doors closed as much as possible to avoid unnecessary run time. The controller displays the current internal temperature. Adjusting the set temperature lower will NOT cause the system to lower the temperature faster.
User Manual for CT Freezer / Refrigerator Beverage-Air SEQUENCE OF OPERATIONS CROSS TEMP The cooler operates based on the air temperature measured by the probe located at the return air. ON Off COMPONENT OPERATION COMPRESSOR Compressor turns on The Compressor Conwhen the air tempera- tact is energized ture at the probe is (ERC 112 - Terminal #1) above the sum of the set point + 2.
User Manual for CT Freezer / Refrigerator Beverage-Air Electronic Controller DEFROST (ESC) UP SELECT (OK) DOWN Control Panel Display Note: Defrost is manual, LED indicator is inoperative.
User Manual for CT Freezer / Refrigerator Beverage-Air Control Panel Connections Changing the Set Point 18 Beverage-Air Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air Electronic Controller Alarms Alarm Trigger Code Automatic Outputs Clearance Comments "Hi" Air temperature is higher than "ALA->Hat• for "ALA->Htd" User configured Bl ink "Hi" with the highest temperature; If configured: cut in alarm relay, beep the buzzer High temperature alarm "Lo" Air temperature is lower than "LAt" for "Ltd'' User configured Blink "Lo" with the lowest temperatu re.
User Manual for CT Freezer / Refrigerator Beverage-Air CLEANING AND MAINTENANCE Cleaning Schedule: Cabinet Condenser coil Gaskets Routine maintenance Daily wipe down Quarterly cleaning Daily inspection, check that hinges are tight to the cabinet. Annually Weekly interior Daily Exterior Cleaning It is much easier to clean on a regular basis than to have to remove stains once they have built up. 1. Wash with a clean sponge and a mild detergent that does not contain chlorine. 3.
User Manual for CT Freezer / Refrigerator Beverage-Air CONDENSER CLEANING Keeping the condenser coil clean is critical to efficient operation. 1. Unplug unit from power supply. CAUTION Rotating fan blade can cause personal injury. Unplug unit from power supply before beginning to clean condenser Remove Screw 2. Remove two Phillips head screws from the top corners of the front panel 3. Lift upwards on the front panel to remove. 4.
User Manual for CT Freezer / Refrigerator Beverage-Air METHODS FOR CLEANING STAINLESS STEEL Cleaning Needed Cleaning Agent Method of Application Affect on Finish Smears and fingerprints Areal 20, Lac-O-Nu, Lumin Wash O’Cedar Cream Polish, Stainless Shine. Rub with cloth as directed on the package. Satisfactory for use on all finishes. Provides barrier film to minimize prints. Allchem Concentrated Cleaner. Apply with damp sponge or cloth. Rub with damp cloth.
User Manual for CT Freezer / Refrigerator Beverage-Air HELP Trouble Diagnosis for the User Malfunction Possible Cause Likely Solution No cooling - unit is silent Unit not plugged in. Fuse or circuit breaker tripped. Power cord plug loose in outlet. Connect to proper voltage circuit Replace fuse or reset breaker.
User Manual for CT Freezer / Refrigerator Beverage-Air FOR THE SERVICE TECH - R290 inform anyone in the area when propane is present in the air. Refrigeration service should only be attempted by a trained trade professional certified to work on R290 systems. Other Information: Here are some critical service items. This list does not qualify anyone to service the unit. It is a reminder and checklist for the service tech.
User Manual for CT Freezer / Refrigerator Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM FOR SINGLE SYSTEM 2 115VAC 60 HZ 3 COMPRESSOR DETAIL WHITE BLACK PE N L 2 R S LSW 1 BLACK WHITE HIGH PRESSURE LIMIT SWITCH C R COMP C S CONDENSER FAN WHITE BLACK FACE HEATER DOOR HEATER 2 6 DEFROST HEATER HEATER SAFETY THERMAL SWITCH 2 5 DIGITAL INPUT SIGNAL EVAP FAN DRAIN TUBE HEATER L.E.D. LAMP DIGITAL INPUT SIGNAL 2 4 POWER SUPPLY LAMP Rev.
User Manual for CT Freezer / Refrigerator Beverage-Air FOR THE SERVICE TECH - WIRING DIAGRAM FOR CT12-12HC-1HC 2 115VAC 60 HZ 3 COMPRESSOR DETAIL DANFOSS CONTROLLER DETAIL WHITE BLACK PE N S1 S2 S3 S4 DI DIGITAL INPUT 6 EVAP SENSOR 5 AIR SENSOR 4 DEFROST S 3 LIGHT COMP C LINE BLACK WHITE HIGH PRESSURE LIMIT SWITCH R NEUTRAL S LSW 1 C COMPRESSOR 2 R FAN 1 2 L CONDENSER FAN WHITE BLACK FACE HEATER DOOR HEATER 2 DIGITAL INPUT CIRCUIT 5VDC FROM CONTROLLER LEGEND 6 DEFR
User Manual for CT Freezer / Refrigerator Beverage-Air LIMITED WARRANTY WARRANTY (Warranty valid in USA and Canada) BEVERAGE-AIR THREE (3) YEAR PARTS AND LABOR WARRANTY: Also, this extended compressor-part only warranty does NOT apply to any electrical controls, condenser, evaporator, fan motors, overload switch, starting relay, capacitors, temperature control, filter/drier, accumulator, refrigeration tubing, wiring harness, labor charges, or supplies which are covered by the warranty above.
User Manual for CT Freezer / Refrigerator Beverage-Air LIMITED WARRANTY (CONTINUED) With the exception of Blast Chillers product is designed for maintaining temperature and not bringing food to a desired temperature therefore cannot be held responsible for this function under warranty. Units must be in a conditioned environment or warranty will be void. Condensing coils must be cleaned at regular intervals. Failure to do so can cause compressor malfunction and will void warranty.
User Manual for CT Freezer / Refrigerator Beverage-Air Warranty Registration Register your product online at beverage-air.com/parts-service or fill out and mail the form below.