4.2 Powering / Operating Time
The microphone units have an integrated rechargeable battery allowing
an operating time of 20 hours.
As soon as the capacity is too low for a satisfactory operation, the operating
control LED will flash. The remaining time of operation is around 60
minutes.
The supplied MCW-D 50 Conference Software indicates the decreasing
battery voltage on a PC or external media control system connected to the
MCW-D 50 control unit.
Rear view microphone unit
4.3 Powering with external CA 2457 Power Supply Unit
The MCW-D microphone units can be also powered with the CA 2457
external power supply unit which can be connected to the DC socket
on the rear of the microphone unit.
During the time the power supply unit is connected, the microphone
unit is also being charged. Please refer also to chapter 8. Battery
Charging with external Power Supply Unit.
Rear view microphone unit
4.4.1 Normal Operating Mode
4.4 Operating Modes
The different operating modes such as Normal, Push-To-Talk or Voice Activation are adjusted with the MCW-D 50 Conference
Software. The standard operating mode is Normal. Please refer also to the appropriate MCW-D 50 Conference Software
manual.
Press the microphone button to switch on the gooseneck
microphone.
Red ring of the gooseneck microphone is illuminated
and the LED is illuminated green: The microphone is ready
for talking.
Using the MCW-D 50-3 control unit 3 participants (e.g. 2 delegates
and 1 chairman) can speak simultaneously. Using the
MCW-D 50-9 up to 9 participants (e.g. 8 delegates and 1 chairman)
can speak simultaneously.
Important:
If the number of open microphones is reached, a
microphone can only be switched on manually
when another microphone unit has been switched
off.
Delegate Chairman
3
3
2
2
8
7
7
8
8