User Manual

Quinta – Control Unit
14
How to combine different rooms – example
In our example the rooms A, B, C are combined.
In room D a separate system with control unit and microphone
units will be operated.
In order to avoid interference between the systems, you must turn
off the control units in room A and C or deactive the radio
module of the control unit via the menu of the control unit or with
the Quinta Conference Software via PC by removing all ticks under
the “Room Combining” - “CU configuration” menu item.
The microphone units which are configured for room A, B, C will
now link to the control unit in room B.
Press the volume control approx. 3 seconds until the
Quinta CU control unit displays “Main Menu”.
Turn the volume control to the right or left until “Room
Combining” is displayed.
Press the volume control to enter the submenu.
Press the volume control once again to enter the submen for the
configuration of the Quinta CU control unit. Turn the volume
control until “(A)” is displayed and press the volume control
to select “(A)” (a tick is displayed under the “A”). Turn the
volume control until “(B)” is displayed and press the volume
control to select “(B)” (a tick is displayed under the “B”). Turn
the volume control until “(C)” is displayed and press the
volume control to select “(C)” (a tick is displayed under the
“C”).
Do not activate room D, as this is a separate system in a separate
room.
In room A and C you must turn off the control units or deactive the
radio module of the control unit via the menu of the control unit
or with the Quinta Conference Software via PC by removing all
ticks under the “Room Combining” - “CU configuration” menu
item.
The microphone units which are configured for room A, B, C will
now link to the control unit in room B.
Configuration of control units and microphone units in the
combined rooms A, B, C and in room D
Important:
The microphone units in the respective rooms must have a
radio link to the control unit.
The configuration for room A, B, C or D is stored in the
appropriate microphone units.
When you have only one Quinta system which you want to
use in one room only, you can keep the factory setting of “A”.