OPERATING INSTRUCTIONS Synexis Wireless Tour Guide System
Synexis – Contents 2 1. Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1.1 Synexis TS2 stationary transmitter, Synexis C8, C10 chargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 1.2 Synexis TH2 handheld transmitter, Synexis TP2 beltpack transmitter, Synexis RP2 beltpack receiver. . . Page 1.3 NiMH rechargeable batteries, batteries . . . . . . . . . . . . . . . . . . .
Synexis – FCC Regulation 3 FCC Regulation FCC ID: OSDSYNEXISTH2 for Synexis TH2 FCC ID: OSDSYNEXISTP2 for Synexis TP2 FCC ID: OSDSYNEXISTS2 for Synexis TS2 FCC ID: OSDSYNEXISRP2 for Synexis RP2 Canada: IC: 3628A-SYNEXISTH2 for Synexis TH2 Canada: IC: 3628A-SYNEXISTP2 for Synexis TP2 Canada: IC: 3628A-SYNEXISTS2 for Synexis TS2 Canada: IC: 3628A-SYNEXISRP2 for Synexis RP2 Part 15.19 Statement NOTICE: This device complies with Part 15 of the FCC Rules [and with RSS-210 of Industry Canada].
Synexis – Safety Instructions 4 Thank you for selecting the Synexis wireless tour guide system from beyerdynamic. Please take some time to read carefully through this manual before using the system. The Synexis tour guide system provides an optimum digital audio transmission for guided tours e.g. in factories or museums or in multilingual conferences e.g. in conjunction with an interpretation system.
Synexis – Safety Instructions 5 • If the equipment causes a blown fuse or a short circuit, disconnect it from the mains and have it checked and repaired. • Do not hold the mains cable with wet hands. There must be no water or dust on the contact pins. In both cases you could receive an electric shock. • The mains cable must be firmly connected. If it is loose there is a fire hazard. • Always pull out the mains cable from the mains and/or from the equipment by the plug – never by the cable.
Synexis – Synexis RP2 Beltpack Receiver 2. Synexis RP2 beltpack receiver 2.1 Controls and indicators 6 Headphone socket, mini jack (3.
Synexis – Synexis RP2 Beltpack Receiver 2.3 • • • • 7 Battery status display The battery status is displayed in 4 stages. If only one bar is displayed, you should recharge the receiver as soon as possible. If the battery frame is flashing, the batteries are empty and have to be replaced or recharged. If the receiver is equipped with rechargeable NiMH batteries, put it into the appropriate charger (e.g. Synexis C8 or C10).
Synexis – Synexis TH2 Handheld Transmitter 3. Synexis TH2 handheld transmitter 3.
Synexis – Synexis TH2 Handheld Transmitter 3.2 • • • 9 How to insert/replace the batteries Slide down the lid of the battery compartment to open the battery compartment . Insert the supplied NiMH rechargeable batteries according to the polarity marks. Before using the transmitter for the first time, the rechargeable batteries inside must be charged e.g. with the Synexis C8 charger. As an alternative you can use two 1.5 V AA alkaline batteries.
Synexis – Synexis TH2 Handheld Transmitter 3.6 • • • 10 How to select a channel Press the on/off button and one of the two arrow-shaped buttons simultaneously for approx. 2 seconds until the channel display will flash. Use the upper or lower arrow-shaped button to select the requested channel. The channel will automatically be stored after approx. 2 seconds. If you press briefly the on/off button , the channel will immediately be stored. 3.7 • • 3.8 • • • • • 3.
Synexis – Synexis TP2 Beltpack Transmitter 4. Synexis TP2 beltpack transmitter 4.1 Controls and indicators 11 On/off switch LED to display operating or charging status (refer also to the chapter “Synexis chargers”) Push-button to mute the microphone Microphone connection, 4-pin mini XLR Set button Line-In input to connect an audio source such as MP3 player, mini stereo jack (3.
Synexis – Synexis TP2 Beltpack Transmitter 4.3 • • • • 4.4 • 12 Battery status display The battery status is displayed in 4 stages. If only one bar is displayed, you should recharge the receiver as soon as possible. If the battery frame is flashing, the batteries are empty and have to be replaced or recharged. If the transmitter is equipped with rechargeable NiMH batteries, put it into the appropriate charger (e.g. Synexis C8 or C10).
Synexis – Synexis TP2 Beltpack Transmitter 4.8 • • 13 How to display the frequency Press the Set button briefly. The frequency will be displayed for a few seconds. 4.9 • How to mute the microphone If you would like to mute the connected microphone, press the mute button . The LED will flash red. “Mute” is displayed . In order to turn off the mute function, press the mute button once again. 4.10. How to connect an audio source • You can connect an audio source (e.g.
Synexis – Synexis TS2 Stationary Transmitter 5. Synexis TS2 stationary transmitter 5.1 Controls and indicators 5.2 14 On/off switch Level control microphone input Level control AUX input OLED display to indicate channel, AF level, frequency and channel lock function Channel selector buttons Set button Level control headphone Headphone connection, 1/4" stereo jack (6.35 mm) (Mix from Aux and Input.
Synexis – Synexis TS2 Stationary Transmitter 5.3 • • • • 5.4 • • 5.5 15 How to select and lock a channel Select a channel with the channel selector buttons . Press the up or down button until the requested channel is displayed . Release the button to store the selected channel. If you would like to lock the selected channel to avoid accidental shifting, hold down the Set button for about 3 seconds. A key symbol will be displayed . The channel is locked.
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 6. Synexis C8 / C10 / C 20 / CHP chargers 6.
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 17 Synexis C10 Power on LED Charging compartments for beltpack transmitters / beltpack receivers Ground Fuse Mains connection Connection to loop through another charger
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 18 Synexis C20 Mains connectio Power on switch with LED Fuse Charging compartment for handheld transmitter Charging compartments for beltpack transmitters / beltpack receivers Synexis CHP DC connection for power adapter Charging compartments for beltpack transmitters / beltpack receivers / handheld transmitters Caution The beltpack transmitter/receiver and handheld transmitter cannot simultaneously be inserted into the sam
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 19 Synexis CHP with beltpack transmitter/receiver and handheld transmitter Synexis CHP with beltpack transmitter/receiver 6.2 • • • • • • How to use the chargers The Synexis chargers have been developed for charging the rechargeable batteries inside the Synexis RP beltpack receiver, Synexis TP beltpack transmitter and Synexis TH handheld transmitter.
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 6.3 20 Power supply Synexis C8 / C10 • Connect the Synexis C8 or C10 charger to AC power. • The charger has no separate on/off switch and is ready for operation when it is connected to AC power. • You can link a maximum of 8 chargers by connecting the first charger via the connection or to the connection or charger and then connect the second charger via the mains connection or to AC power.
Synexis – Synexis C8 / C10 / C20 / CHP Chargers 21 Synexis CHP • Connect the Synexis C20 charger to AC power. • Switch on the charger with the power on switch. Synexis CHP 6.4 • • • • • Charging When the Synexis beltpack receivers / beltpack transmitters are equipped with rechargeable batteries, put them into the appropriate charging compartments of the Synexis C8, C10, C20 or CHP charger.
Synexis – Trouble Shooting 7. 22 General instructions for a trouble-free operation • Make sure that the transmitter and receiver are on the same frequency. • Check the batteries and replace or recharge them if necessary. • The transmission range depends on various factors such as local, constructional conditions. It can be reduced due to shadowing effects of metal partitions (e.g. in lifts), high production machinery and reflections from metallic objects.
Synexis – Components 9. Components Synexis RP2 Synexis TH2 Synexis TP2 Synexis TS2 Synexis C8 Synexis C10 Synexis C20 Synexis CHP 10. 23 Beltpack receiver, frequency range 216 MHz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 721.468 Handheld transmitter, frequency range 216 MHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Order # 721.476 Beltpack transmitter, frequency range 216 MHz . . . . . . . . . .
Synexis – Frequencies 12. 24 Frequencies Channel display Frequency 1 216.025 MHz 2 216.075 MHz 3 216.125 MHz 4 216.175 MHz 5 216.225 MHz 6 216.275 MHz 7 216.325 MHz 8 216.375 MHz 9 216.425 MHz 10 216.525 MHz 11 216.575 MHz 12 216.625 MHz 13 216.675 MHz 14 216.725 MHz 15 216.775 MHz 16 216.825 MHz 17 216.875 MHz 18 216.925 MHz 19 216.
Synexis – Technical Specifications 13. Technical specifications Synexis RP2 beltpack receiver Oscillation type . . . . . . . . . . . . . . . . . . . . . . . . . . PLL synthesized control OSC Carrier frequency range. . . . . . . . . . . . . . . . . . . . 216.025 - 216.975 MHz Adjustable channel . . . . . . . . . . . . . . . . . . . . . . . 19 channels Frequency response . . . . . . . . . . . . . . . . . . . . . . . 100 Hz - 10 kHz Dynamic range . . . . . . . . . . . . . . . . . . . . . . . . . .
Synexis – Technical Specifications Synexis TS2 stationary transmitter Oscillation type . . . . . . . . . . . . . . . . . . . . . . . . . . PLL synthesized control OSC Carrier frequency range. . . . . . . . . . . . . . . . . . . . 216.025 - 216.975 MHz Adjustable channel . . . . . . . . . . . . . . . . . . . . . . . 19 channels Frequency response Headphone* . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Hz - 10 kHz RP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weitere Vertriebspartner weltweit finden Sie unter www.beyerdynamic.com For further distributors worldwide, please go to www.beyerdynamic.com E 1/BA Synexis (08.10) • Änderungen und Irrtümer vorbehalten • Subject to change without notice • Sujet à changement sans préavis beyerdynamic GmbH & Co. KG Theresienstr. 8 | 74072 Heilbronn – Germany Tel. +49 (0) 7131 / 617 - 0 | Fax +49 (0) 7131 / 617 - 204 info@beyerdynamic.de | www.beyerdynamic.