Wire selection for handset / line connection (internal jumpers with CR-200)
As handset and telephone connection cables can be wired in different ways, the CR-
200 is universally adaptable.
If, when making your first recordings, you discover, that when you connect for example
the handset, the volume difference between you and the other person is too big, you
can pull jumpers inside the unit. To do so, first disconnect all cables from the CR-200
and then carefully open the housing.
Now, pull out either the two outer jumpers (green arrows) or the two inner jumpers (blue
arrows) of the group of four (marked red), according to this drawing *:
After that, first close the housing completely. Only then, reconnect the cables to the CR-
200 to put it into operation again. If you’re not sure, let this configuration change be
done by a telephone engineer.
* After that, do some test recordings. If the recording quality is worse than before, try
pulling the other pair of jumpers.
NOTE: Different volume levels of both parties of the conversation recorded are usually
depending on the phone set which the CallRecorder is connected to. They sometimes
cannot be avoided completely even by the measures mentioned above. This is no fault
of the CallRecorder device.