Phobos N L BT installation manual version 130308 Thalia control board tuned to you Professional installation required welding might be needed
INSTALLATION SAFETY GATE AUTOMATION INSTALLATION SAFETY While the manufacturer has designed the system under strict safety standards, it is ultimately the installers responsibility to follow and comply with national and local laws, codes and safety standards that apply to the mechanical, electrical and operational aspects of the gate automation system.
OPERATIONAL SAFETY 3 GENERAL SAFETY WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or property. • Automation should be installed on a gate which is moving freely. Any issue with the smooth opening of closing of a gate will not be corrected by adding automation. • Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.
TABLE OF CONTENTS 4 Installation Safety ................................................................................................................................................. 2 Operational Safety ................................................................................................................................................ 3 Applications and Capacities ..............................................................................................................................
APPLICATIONS & CAPACITIES Important. This product is intended to be installed and serviced by a professional technician. The product warranty may be voided if installed or serviced by a unqualified person.
POST BRACKET INSTALLATION 6 gate post gate hinge from the center of the hinge must be between 7” & 7-1/2” 7-1/2” is best Depending on the size of the post, the type of hinge and its placement, the post bracket might have to be mounted offset to the gate post.
GATE BRACKET INSTALLATION 7 gate gate post hinge gate bracket post bracket 32” This measurement is taken with the gate fully closed magnet Install the magnet holder into the gate bracket magnet The top surface of both post and gate bracket must be leveled between the two GATE CLOSED GATE OPEN hinge center-line gate bracket post bracket post bracket post bracket line gate bracket When the gate is on its fully open, or fully closed position, the distance from the center of the mounting hole o
PUSH TO OPEN INSTALLATION WARNING: Push to open installations are not standard installations. The post bracket should require modifications and/or welding. The following illustrations do not represent the actual assembly of the post bracket.
THE ACTUATOR CABLE 9 1. Strip about 1-1/2” off the outer jacket of the motor cable. Install the o-ring over the cable so that it is about 1/2” from the 1-1/2” RUBBER O-RING edge of the outer jacket 16/3 SJTOOW CABLE 2. Turn the actuator upside down. Connect the white wire to terminal 1; the red wire to terminal 2; and the black wire to terminal 3 white red black 3.
MOUNTING THE ACTUATOR 10 snap ring flat washer spacer collar pivot bolt flat washer lock nut snap ring Attach the actuator to the mounting brackets as shown on the images above. DO NOT INSTALL THE SNAP RINGS YET!!! Place them in a secure location. Install the snap rings only once you have completely finalized the installation and all adjustments.
SETTING THE LIMITS 11 1) SET TO MANUAL OPERATION Disengage the drive gear by using the triangular key and turning clockwise. 2) SET THE CLOSE LIMIT - Push the gate to its fully closed position. Remove the screw that holds the proximity sensor at the front end of the actuator. Slide it back so that the back end of the sensor housing is 3-1/2” from the center of the drive carriage and reattach screw that secures sensor in place. 3-1/2” 3) SET THE OPEN LIMIT - Push the gate to its fully open position.
INSTALLING THE STANDARD CONTROL BOX 12 Mounting the enclosure 4” 9-1/4” 6” 1/1 7 -1 Several sizes knock-out punch conduit entries are provided Using the lid screws port holes to fix the enclosure, ensures weatherproof protection of the electronic components. Use plastic anchors for best results Connecting power Federal and local electrical codes must be followed. 120 Volts, single phase power is connected to the terminal strip on the + lower left corner of the control board as shown.
INSTALLING THE OPTIONAL CONTROL BOX Mounting the enclosure Use the mounting holes on the top and bottom flanges 13 Do not perforate the top of the enclosure of the enclosure. Do not drill through the interior of the enclosure. Bring all your wiring and/or conduits through the bottom of the enclosure.
MOTOR CONNECTIONS 14 + OK █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75 Motor #1 For single gate installations, connect your motor wires to Motor 1 motor output (terminals 10 & 11), and Motor 1 limit input (terminal 42).
QUICK SETUP MENU 15 Quick Setup Menu flow chart LANGUAGE ► TYPE ITALIAN FRENCH GERMAN ENGLISH SPANISH NUMBER ► DIRECTION ► OF MOTORS ► ELI PHOBOS IGEA 2 1 PRESET INT EXT ► AUTOSET AR SR AC SC IND ► MEMORIZE REMOTES HIDDEN BUTTON OK ► RELEASE ► DESIRED ► BUTTON END KO ► Quick Setup Menu navigation + Pressing the [+] button scrolls UP OK █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61
QUICK SETUP MENU 16 STEP 3. Select the type of operator scroll down using the [-] button and look for “phob” (phobos) press [ok] to select next the screen will display: “n. mot” (number of motors). + + + - - - OK OK OK STEP 4. Set the number of motors connected if two motors are connected, press [ok] while “2” is shown on the screen if only one motor is connected, press the [-] button... … and then press [ok] to select. + + - - - OK OK OK + STEP 5.
QUICK SETUP MENU 17 PRESETS FEATURES AUTOMATIC CLOSING TIMER AR SR AC SC IND AUTOMATIC RESIDENTIAL SEMI-AUTOMATIC RESIDENTIAL AUTOMATIC COMMERCIAL SEMI-AUTOMATIC COMMERCIAL INDUSTRIAL x x PRE-ALARM x x UNINTERRUPTED OPEN CYCLE x x INSTANT REVERSE ON CLOSING x x x HOLD TO RUN QUICK REMOTE PROGRAMMING x x x x Automatic Closing Timer: Automatically closes the gate after gate fully opens and all safety devices are cleared.
QUICK SETUP MENU 18 STEP 7. Run the AUTOSET after selecting your preset, the screen will display “prog” (programming) for a few seconds the screen will the display “autoset” + - be aware that the gate will run at full torque during the process. press [ok] when ready OK + + OK the motor(s) will run full open and close cycles more than once... + - make sure that the path of the gate is clear of traffic and obstructions.
ACCESSORY CONNECTIONS 2 51 4 V A – 2 cc 52 4V ess – Acc or 24 y V ess po VS or w af y p er e [+ ow [-] er ] [+ ] 19 ACCESSORY POWER Name Description 50 51 52 - 24 V + 24 V + 24 V-Safe Accessory power negative common Accessory power positive Positive power when gate is not closed █ █ █ 50 51 52 pe ni ng ) Terminal 50 – 24 volts accessories and peripherals can be powered from terminals 50 and 51 C 61 OM M – O I 62 C1 – N – IC STA 2– R PE T/S D TO (p P ar tia lo COMMAND INPUTS Terminal Na
70 – The Thalia board provides one STOP command input, and two programmable obstruction sensing device inputs, SAFE1 and SAFE2. All 3 safety inputs are N.C. (normally closed) contacts. Both SAFE 1 and 2 have a device supervision circuit labeled FAULT. Fault inputs, when enabled, are all normally open. Below is a table with the terminal numbers and its █ corresponding functions and default values.
AUXILIARY OUTPUTS 20 & The Thalia board has two auxiliary outputs. The first (20 & 21), is a 24 volt, courtesy light output that will activate upon activation of the gate, and will remain on for 90 seconds after the gate has closed. The second output labeled AUX 3 (26 & 27), is defaulted as second channel radio receiver output, but can be reprogrammed to perform any of the following functions under the LOGIC sub-menu: 2 LI 1 – GH 2 T 4 26 OU VOL T & T C 2 P N. 7 – UT OU O.
NAVIGATING THE MAIN MENU 22 Main Programming Menu navigation + - Pressing the [+] button scrolls up or increases value OK █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 75 BACK + UP - DOWN OK ENTER Pressing the [-] button scrolls down or decreases value Pressing the [OK] button serves as ENTER Pressing [+] and [-] at the same time serves as BACK (Parameters) PARAM Sub-m
PROGRAMMING MENU MAIN S ELECTION DEFAULT RANGE PARAM > OPEN DELAY TIME Motor 2 opening delay in s econds 1 0-10 CLS DELAY TIME Motor 1 clos ing delay in s econds 1 0-10 Auto-clos e time adjus tment in s econds 10 1-180 TRF. LGHT.CLR. T Traffic zone clear time adjus tment in s econds 40 1-180 OP. DIS T. S LOWD S lowdown s tarting dis tance from end of open travel expres s ed in percentage 10 0-50 CL. DIS T.
OTHER ACCESSORIES CONNECTIONS 24 Dedicated power supply MAGNETIC LOCK WIRING USING BFT 24V AC/DC RELAY RED (+24V) WHITE (-24V) YELLOW (normally closed contact) BLUE (common) P/N: KRELAY24V BATTERY BACKUP WIRING DIAGRAM Transformer SBS – battery backup board 5 3 20 1 4 3 4 2 5 Power plug BK GY + - 1 OK 2 12v batteries █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ █ 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72
MAINTENANCE 25 DISCONNECT ALL POWER INCLUDING BATTERIES IF APPLICABLE BEFORE PERFORMING ANY MAINTENANCE OR REPAIR TO THE ACTUATORS MAINTENANCE - Inspect the screw-drive gears for lubrication, debris and cleanness at least once a year. For actuators installed in areas where dirt and dust are a concern, maintenance should be done at shorter intervals. Keep the screw-drive lubricated using BFT grease part number: I101115. Do not apply grease if gears are dirty.
REPLACEMENT PARTS 26 Thalia control board Includes enclosure and transformer P/N: D113745 00001 Secondary fuse 3.15 Amps, slow-blow 5mm x 20mm Primary fuse 2.
OPTIONS & ACCESSORIES THALIA P LE-B P/N: KTHALIA12U Large 12” x 14” control board enclosure. Includes battery backup with (2) 12V, 9 Ah batteries. The Thalia “P” version features additional programmable inputs and outputs for greater integration capabilities. Dedicated external lock output eliminates the need for additional power supplies or relays to drive your magnetic or solenoid lock. 27 ECOSOL THALIA Solar powered system.
NUMBER OF MOTORS ► DIRECTION INT EXT ► 32" PRESET ► AUTOSET ► HIDDEN BUTTON MEMORIZE REMOTES ► RELEASE END ► AT A GLANCE QUICK REFERENCE ► 2 1 AR SR AC SC IND OK ► DESIRED ► BUTTON KO 120 V NEUTRAL ⵀ 2.5A SLOW BLOW 120 V LINE ⵀ Phobos N L BT Geometry TYPE ELI PHOBOS IGEA 3.15A SLOW BLOW ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ ▊ 10 11 14 15 20 21 26 27 40 41 42 43 44 45 50 51 52 60 61 62 70 71 72 73 74 R BK R BK W W AUX 3 n.o.