Instructions / Assembly
-14-
[Connection of Wires]
1. Indoor unit (fig.12)
• Open the panel upwards and open directly to
the maximum.
• Open the electrical cover.
• Secure the connection wires to the terminal
block according to the wiring diagram on the
electrical cover.
• Press the connecting wire tightly with the
pressure plate.
• Close the electrical cover, secure the electrical cover with screws,
and close the panel.
Note: Some models may not be able to directly pass through the cable hole into the
electric control box, and the above steps need to be removed after removing the middle
frame.
2. Outdoor unit (fig.13)
• Unscrew the handle cover fixing screw and open the handle cover.
• Secure the connection wires to the terminal block
according to the wiring diagram on the handle cover.
• Press the connecting wire tightly with the pressure
plate.
• Put the handle cover back and fasten with the screws.
• If customers need to extend or replace the power
cord, please refer to Table 3 for specifications.
Table 3
Power
connecting wires
Sign
control wire
Power cord
Max Length 11yard 11yard 5.5yard
5K/7K/9K/12K Cross sectional area ≥0.00155inch² ≥0.00155inch² ≥0.00155inch²
16K/18K ≥0.00233inch² ≥0.00233inch² ≥0.00233inch²
18K/21K/24K/28K ≥0.00388inch² ≥0.00116inch² ≥0.00388inch²
9K/12K(115V)
≥0.00233inch² ≥0.00233inch² ≥0.00233inch²
Electric
Wiring diagram
Close
Open
Fig 12
Handle cover
Screw
Wiring diagram
Fig 13