Instructions / Assembly

-16-
Notes:
Earthing screw must use special screw (stainless machining screws or copper screws M4)
Ensure that all wires are securely connected, will not loose or separate.
Ensure that wire connections are carried out according to the wiring diagram of the air
conditioner.
The above figures are only schematic, and they may be slightly different from the actual
appliances you select.
Tube Strapping
Strapping with PVC Protective tape must be careful, do not damage the pipeline and
drain pipe.
Strapping should start from the lower part of the outdoor unit to the indoor unit.
Fix the PVC tape with adhesive tape to prevent loosing.
Drainpipe should slightly slide down outwards to ensure drainage well.
When the indoor unit is lower than the outdoor unit, bend the tube to proper extent to
prevent water draining into house.
Fix the tube bundle with tube clamps on the wall.
Allow enough space between discharge pipe and the ground. Do not put the discharge
pipe in water or ditch.
Seal the external wall holes with sealing gum or putty.
Wall
Clamp
PVC protect tape
Fig 14