Instructions / Assembly
-18-
[Drainage]
1. No need drainage treatment
In regions where become cold in the winter, don't install the drain elbow joint to prevent
drain water from freezing and causing the fan to be damaged. This drainage treatment
is not necessary for cooling-only type air conditioner.
2. When need drainage treatment
Please use drain elbow joint (in accessory bag). Outdoor unit should be placed on blocks.
Installation for the cover of valve
For the whole unit that individual cover of valve is available (refer to packing list), the installing
method is as follow:
After connecting the connection pipes between indoor and outdoor units followed by the
installing method mentioned above, take out the cover of valve from the accessory bag, and
fix it on the side of outdoor unit with three corresponding screws. (inside the accessory bag)
Fig 16
Drain pipe (buy it by user)
Chassis(outdoor)
Elbow joint
Fig 17
Screw
Cover of valve