system. The compiler chose to ignore all blocks which are isolated from
any I/O blocks and, therefore, do not affect the rest of the system in any way.
Message: Total maximal duration of delays exceeded in the unit #_.
Explanation: The number of delay blocks, and their combined delay ranges,
exceeds the maximum capability of this unit. Currently, any single
NEXIA unit can provide a maximum of 15 seconds of delay blocks.
Matrix Mixers with Delay also contribute to this total, consuming
1 second per input channel.
Allocation of DSP blocks to DSPs
Message: Allocating blocks to DSPs...failed to set up a feasible DSP task
schedule in the unit #__.
Explanation: Although the total DSP power in the NEXIA unit is sufficient, compile
was not able to distribute the component objects among the
available DSPs. When the DSP load approaches 100%, it becomes
crucial that the objects be distributed more uniformly. Try moving
certain objects to another unit, or replace them with a comparable
set of smaller objects (within the same unit). Otherwise, it may be
necessary to add an additional NEXIA unit to the system, and move
large DSP blocks into it.
Assigning control blocks to NEXIA units
Message: Some unconnected control blocks have been ignored.
Explanation: Control blocks with no connections have been excluded from the
system. Only Logic Gate , Logic Delay, and Remote Preset Button
blocks can be ignored. When connected to the system, control dialogs
for ignored blocks cannot be accessed.