Manual

System Control
1 = muted
Crosspoint Mute AMMUTEXP SET, GET 1 1 =unmuted
0 = muted
Logic Output AMLOGOUT GET 2 0 = off
1 = on
* Can contain a decimal number.
Note: Typically, Index1 represents the input/row, and Index2 represents the output/column.
However, Automixers have only a single output and, therefore, Index2 is not used to specify an
output/column.
Example: Set Device 1 Automixer Crosspoint Mute at Instance 3 Crosspoint 1 to muted.
Command Dev # Attribute Inst ID Index 1 Index 2 Value Line Feed
SET 1 AMMUTEXP 3 1 None 0 <LF>
Result: SET 1 AMMUTEXP 3 1 0 <LF> (Automixers have only 1 output, so Index2 is not
required)
Matrix Mixer Attribute Commands Index Value Range
Input Level MMLVLIN
SET, SETL, GET, GETL, INC,
DEC
1 -100 ~ 12 *
Output Level MMLVLOUT
SET, SETL, GET, GETL, INC,
DEC
2 -100 ~ 12 *
Input Mute MMMUTEIN SET, GET 1 0 = unmuted
1 = muted
Output Mute MMMUTEOUT SET, GET 2 0 = unmuted
1 = muted
Crosspoint Level MMLVLXP
SET, SETL, GET, GETL, INC,
DEC
1 & 2 -100 ~ 0 *
Crosspoint Mute MMMUTEXP SET, GET 1 & 2 1 = unmuted
0 = muted
* Can contain a decimal number.
Note: For attributes with 2 Index fields, Index1 is the input/row, and Index2 is the output/column.
179