Introduction
NEXIA® CS
The DSP conference system shall provide ten balanced mic/line inputs
and six balanced mic/line outputs on plug-in barrier-strip connectors.
Inputs and outputs shall be analog, with internal 24-bit A/D & D/A
converters operating at a sample rate of 48kHz. All internal processing
shall be digital (DSP). NexLink connections shall allow sharing of
digital audio within multi-unit systems.
Software shall be provided for creating/connecting DSP system
components within each hardware unit. Available system components shall
include (but not be limited to) various forms of: mixers, equalizers,
filters, crossovers, dynamics/gain controls, routers, delays, remote
controls, meters, generators, and diagnostics. Ethernet communications
shall be utilized for software control and configuration. After initial
programming, processors may be controlled via dedicated software
screens, third-party RS-232 control systems, and/or optional remote
control devices. Software shall operate on a PC computer, with network
card installed, running Windows® XP Professional/Vista. The DSP
conference system shall be CE marked, UL listed, and carry a five-year
warranty.
The DSP conference system shall be NEXIA® CS.
NEXIA® PM
The DSP presentation mixer shall provide four balanced mic/line inputs
and three balanced stereo line outputs on plug-in barrier-strip
connectors, plus six unbalanced stereo line inputs on RCA connectors.
Inputs and outputs shall be analog, with internal 24-bit A/D & D/A
converters operating at a sample rate of 48kHz. All internal processing
shall be digital (DSP). NexLink connections shall allow sharing of
digital audio within multi-unit systems.
Software shall be provided for creating/connecting DSP system
components within each hardware unit. Available system components shall
include (but not be limited to) various forms of: mixers, equalizers,
filters, crossovers, dynamics/gain controls, routers, delays, remote
controls, meters, generators, and diagnostics. Ethernet communications
shall be utilized for software control and configuration. After initial
programming, processors may be controlled via dedicated software
screens, third-party RS-232 control systems, and/or optional remote
control devices. Software shall operate on a PC computer, with network
card installed, running Windows® XP Professional/Vista. The DSP
presentation mixer shall be CE marked, UL listed, and carry a five-year
warranty.
The DSP presentation mixer shall be NEXIA® PM.
NEXIA® SP
21