User Manual

Software Tools
Gang Group
Gang Group allows multiple controls of
the same type to have combined
operation. A Gang Group must first be
created in this list. Then multiple controls
of the same type may be assigned to
that group via the Property Sheet
.
NOTE: Instance ID (or Instance ID Tag),
DSP Block Type, Attribute, and
Input/Output must be assigned for
objects in a gang, even to achieve
proper control behavior in Test Mode
.
Gang Groups are created or removed
using Add and Delete.
When a new Gang Group is added, a
Toggle Button control appears, which is
already assigned to gang/un-gang all of
the controls in that Gang Group. Gang
controls may be deleted if not needed.
User-created Toggle Button
controls
may also be assigned as Gang controls.
When assigning controls to a Gang Group (via the Property Sheet
), some or all of the controls may be
assigned as Master. Gang Group and Master control behavior varies by control type.
Toggle Button controls: When the state of a Master control is toggled (on/off) by clicking on it, other Master
controls in that Gang will also toggle (on/off), regardless of their original state. Non-Master controls will
simply assume the same state (on/off) as the Master control.
Fader, Edit, and Edit Spin controls: When the setting of a Master control is changed, all other controls in that
Gang are changed accordingly, so as to maintain the same relative offsets. The range of the Master control
is restricted, so that no other (offset) controls may travel outside of their range. When a non-Master control
setting is changed, no other controls in that Gang are affected.
Graph controls: Graphs cannot be assigned as Master controls. All Graph controls within a Gang will follow
the active control exactly, on an individual filter basis. With Parametric EQs or All-Pass Filters it is possible
to gang controls that have a different number of filter bands. In this case, only the common filter bands
(those that are first in initial numerical order) are ganged together.
NOTE: If a ganged control is modified as the result of a preset recall, then no ganging behavior occurs.
39