RP-L1, RP-L2, & RP-S4 Remote Panels Instruction Manual Biamp Systems | 9300 S.W. Gemini Drive | Beaverton, OR | 97008 | USA | +1.503.641.7287 | www.biamp.
RP-L1 & RP-L2 Remote Panels (Level) RP-L1: The RP-L1 is a remote control panel, which consists of a single 25kΩ linear taper potentiometer mounted on a grey ‘decorator’ style cover plate, with a single-gang ‘cut-in’ style PVC electrical back-box and a pre-wired pigtail. The RP-L1 may be used to provide remote control of volume levels as specified for the following BIAMP products: products 801 Mic/Line Mixer . . . . . . . 601 Mic/Line Mixer . . . . . . . 301 Mic/Line Mixer . . . . . . .
RP-S4 Remote Panel (Switches) RP-S4: The RP-S4 is a remote control panel, which consists of four doublepole*/double-throw switches mounted on a grey ‘decorator’ style cover plate, with a single-gang ‘cut-in’ style PVC electrical back-box and four pre-wired pigtails. The RP-S4 may be used to provide remote control switching as specified for the following BIAMP products: products 801 Mic/Line Mixer . . . . . . . 601 Mic/Line Mixer . . . . . . . 301 Mic/Line Mixer . . . . . . . CMA Series Mixer/Amplifiers . .
Back-Box Installation Back-Box flange Remove the back-box from the front panel (controls). Route cables through a ‘knock-out’ hole on the rear of the back-box. Install the back-box in a wall or panel, in the same orientation as any standard single-gang electrical box. The mounting surface may be from 1/8” to 1” thick. (3.175mm to 25.4mm) The mounting cavity must be exactly 3.6” high, 2.25” wide, and at least 2.75” deep. (91.44mm H x 57.15mm W x 69.