Vocia® TTS-1 and TTS-1nc Operation Manual January 2013 Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.
TABLE OF CONTENTS VOCIA TEXT-TO-SPEECH SERVER 1 (TTS-1) FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SETUP AND USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FRONT PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VOCIA TEXT-TO-SPEECH SERVER 1 (TTS-1) The TTS-1 is a networked text-to-speech engine that supports the creation of browser-based courtesy announcements. The TTS-1nc performs the same functions as the TTS-1 in addition it is able to integrate to TAP enabled nurse call systems. The TTS-1 and TTS-1nc use Ethernet-based control protocols in conjunction with A Vocia Message Server 1 to function within a Biamp® Vocia® system and constructs announcements using a set of user-defined templates.
TTS-1 SETUP AND USE Overview The Vocia Text to Speech Server 1 (TTS-1) and The Vocia Text to Speech Server 1 Nurse Call (TTS-1nc) are designed to work in conjunction with a Vocia Message Server 1 (MS-1) to enable text to speech messaging as part of a Vocia system solution. Voice fonts are available to suit regional languages. The TTS-1nc also facilitates integration via RS-232 to Nurse call systems that make use of the TAP protocol. Rauland Responder 4 and 5 are supported natively.
TTS-1 FRONT PANEL Power/ Network Front Panel The TTS-1 features one power indication LED on the front panel: 1. Not illuminated: The device is not powered. 2. Flashing green: The unit is receiving power but not data, or the unit has not been configured correctly. 3. Solid green: The unit is operational. Power supply and network traffic are functional.
TTS-1 REAR PANEL MSB LSB Device ID LAN1: Control LAN2: CobranetTM LAN3: Spare LAN4: Spare O Model TTS-1 BIAMP SYSTEMS RS232 Port AC Power Entrance (IEC) USB Ports LAN-1 LAN-3 Device ID (control) (Spare) LAN-2 LAN-4 (CobraNet) (Spare) Device ID The rotary ID switches are located on the back of the TTS-1 and give the unit a unique Device ID. The switches are in hexadecimal format. All TTS-1 units must have a unique Device ID to function properly within a Vocia Paging World (i.e.
TTS-1 REAR PANEL AC Power Entrance (IEC) The IEC power entrance provides for connection of the appropriate power cord (included with unit). An internal universal switching power supply accepts 100–240VAC @ 50/60Hz, with a maximum power consumption of 350 watts. CAUTION: Do not remove or defeat the ground prong on the power cord, as this will constitute a shock hazard. Equipment should be connected to a mains socket outlet with a protective earthing connection.
PHYSICAL CONNECTIONS RS-232 Nurse Call Physical Connection The TTS-1nc allows interfacing to Nurse call systems via RS-232 and supports the TAP protocol. Currently the TTS-1nc supports Rauland Responder 4 and 5 natively. Two connection modes are supported. Active Mode is supported where the TTS-1nc and Nurse call system are the only devices used. This provides a fully monitored connection between the Nurse call system and the TTS-1.
INSTALLATION Installation The TTS-1 requires one 1.75 inch (44.45 mm) high and 19 inch (483 mm) wide rack space with 17inch (432 mm) depth. Mounting the unit using four screws with washers will prevent marring of the front panel. PVC or nylon washers are appropriate. When installing the rack ears, please note that the hardware is not symmetrical.
TTS-1 SPECIFICATIONS Text-to-Speech Server 1 SPECIFICATIONS Default IP address Weight: 192.168.1.201 Power Consumption (100–240VAC 50/60Hz): Ambient Operating Temperature Range: < 350 watts Dimensions: Height: Width: Depth: 12 lb (5.4 kg) 0.75 inches (44.5 mm) 19 inches (483 mm) 17.
TTS-1 WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to the terms and conditions set forth below.
COMPLIANCE 12