VOCIA VOICE OVER IP INTERFACE (VOIP-1) REAR PANEL
Network
The VOIP-1 is designed to be used in a single Vocia World and utilizes the Vocia CobraNet LAN to communicate with the rest of the Vocia system.
The unit has two monitored RJ-45 Ethernet network connectors that allow a redundant connection to be utilized if required. The primary connection
will always have priority over the Secondary connection. The secondary connection can be disabled in Vocia software if not required. The RJ-45
connectors use two LEDs to indicate Ethernet link and network activity (see table below).
Left LED Right LED Description
None None No Data Connectivity or CobraNet activity
None Flashing green Link established
Solid amber Flashing green Link established and CobraNet activity detected. The unit is acting as a CobraNet Performer.
Flashing amber Flashing green Link established and CobraNet activity detected. The unit is acting as a CobraNet Conductor.
Flashing amber None CobraNet fault. Check cabling and conguration for errors.
The maximum distance between any unit and an Ethernet switch is 328 feet (100 meters) when using copper cabling. Additional Ethernet
switches and/or ber-optic cable can be used to further extend distances between units on a network. Please note that CobraNet limits
network extensions to seven hops (one-way transmissions) within a network.
VoIP Connections
Each RJ-45 VoIP connection will support up to two lines. The connection will act as a third-party SIP endpoint.
The VOIP-1-2 unit can support up to two VoIP lines via 1 RJ-45 connector.
The VOIP-1-4 unit can support up to four VoIP lines via 2 RJ-45 connectors.