Installation Guide

22
BIG ASS FAN 4900
WWW.BIGASSFANS.COM ©2013 DELTA T CORP. ALL RIGHTS RESERVED
Electrical Installation (cont.)
Wiring: 100–125V single-phase fan controllers
WARNING: Wait three minutes after disconnecting before servicing!
:$51,1*,PSURSHULQVWDOODWLRQFDQFDXVHHOHFWULFVKRFNRUGDPDJHWRWKHPRWRUDQGFRQWUROOHU$TXDOL¿HGHOHFWULFLDQ
should perform the installation.
7KHGLDJUDPEHORZVKRZVZLULQJIRUD±9ĭ+]IDQFRQWUROOHU6HHSDJHIRUGHWDLOHGSRZHUUHTXLUHPHQWV
The fan includes a 50-ft (15.2 m) pre-attached motor cord and a 10-ft (3 m) pre-attached controller AC supply cord with a NEMA 5-20P
plug.
Motor Output Wiring
3W plus GND
AC Input Wiring
2W plus GND
The L2 terminal is not used when wiring the fan
FRQWUROOHUIRU±9ĭ7KLVIDQFRQWUROOHUGRHV
not include a disconnect.
Note: This fan controller does not contain fusing!
Power must be supplied to this controller via a
dedicated circuit breaker or properly fused disconnect!
Motor Cord
Controller with attached AC supply
cord and NEMA 5-20P plug
U/T1 V/T2 W/T3
PE
L1 L2 N
1 2 5 6 13A13B13C 14 30 16 1725 4 11
1 2 5 6 13A13B13C 14 30 16 1725 4 11
BLACK
RED
WHITE
BLACK
G
R
E
E
N
W
/
Y
E
L
L
O
W
BLACK
WHITE
G
R
E
E
N
W
/
Y
E
L
L
O
W
WHITE