User Manual

8
SYSTEM AIR PURGE PROCEDURE
Perform the following Air Purge Procedure to remove any air that may have been introduced into the
hydraulic system as a result of product shipment and handing. This step is to be completed without any
load pressure.
1. Firmly close the Release Valve by turning it clockwise.
2. Press the tip of the Hydraulic Hose Coupling against a hard surface and pump the pump handle.
3. Continue pumping until the hydraulic fluid coming out from the end of the coupler tip is free of air
bubbles.
4. Check the oil level and add oil if necessary. (See instruction in Maintenance Section “To Add Oil”.)
5. Turn the Release Valve counter-clockwise to release the pressure in the pump and hose.