User Manual

1 — SAFETY
5
BEFORE OPERATION DURING OPERATION
Ensure the following general safety precautions are
followed before operating the articulating boom lift:
ALWAYS inspect the usage area for potential
hazards, such as unstable or unlevel surfaces,
overhead obstructions and electrically charged wires
or conductors. ALWAYS watch for moving vehicles
in the operating area.
ALWAYS conduct a thorough inspection of the
machine before operation. Check for damaged or
worn parts, hydraulic leaks, damaged wiring, loose
wiring conductors, damaged outriggers, low tire
pressure, uneven tire wear or tire damage. Check for
any improperly operating components. NEVER
operate equipment if any damage is observed or
suspected. Repair damaged or malfunctioning
equipment before operation.
ALWAYS wear proper clothing and footgear. Wear
protective equipment as required by government
regulations. Keep loose clothing, jewelry, gloves and
hair away from moving parts.
ALWAYS wear a safety harness and energy-
absorbing lanyard, such as a safety harness and
lanyard provided by Bil-Jax.
ALWAYS inspect platform floor and outrigger
footpads for mud, grease, debris or other foreign
material. ALWAYS remove any such material from
the equipment before operation.
ALWAYS tag any part of the equipment known or
suspected to be damaged or malfunctioning.
ALWAYS remove a malfunctioning, damaged or
defective machine from service. NEVER operate a
machine that has any known or suspected defect.
ALWAYS comply with the instructions found in
Safety and/or Service Bulletins distributed by the
manufacturer. Bulletins may contain critical
procedures that supersede the information
contained in manuals.
NEVER operate this equipment while under the
influence of drugs or alcohol, while taking
prescription medications that may leave the operator
drowsy or prone to dizziness, or while feeling ill.
NEVER modify the equipment in any way that would
affect its original design or operation.
NEVER deface, modify or obscure any decals or
markings on equipment.
NEVER operate the equipment in any way for which
it is not intended.
Ensure the following general safety precautions are
followed while operating the articulating boom lift:
ALWAYS position lift away from power lines to
ensure that no part of the lift can accidentally reach
into an unsafe area. This includes full extension of
the boom through 700º rotation.
DANGER
This machine is NOT insulated for use near
electrical power lines and DOES NOT provide
protection from contact with or close proximity
to any electrically charged conductor. Operator
must maintain safe clearances at all times (3.05
meters minimum) and must always allow for
platform movement due to gusty winds. Always
contact power company before working near
power lines. Assume every power line is live.
Power lines can be blown by the wind. Refer to
Table 1-1 for minimum safe approach distances
between the machine and electrical power lines.
Table 1-1. Minimum Safe Approach Distances
ALWAYS keep away from a machine that is
exposed to energized power lines. If the machine
contacts energized power lines, NEVER touch or
operate the machine until power lines are shut off.
ALWAYS operate only on a firm and level surface.
NEVER operate on surfaces that do not support the
equipment with its rated load capacity or on surfaces
that do not support force exerted by the outriggers
during boom operation. Operate only on surfaces
that can support a pressure of 1.8 kg/cm
2
(25 psi) to
ensure safe operation.
ALWAYS keep personnel away from potential pinch
and shear points and from potential crush hazards
as indicated by decals attached to the machine.
ALWAYS keep the safety bar lowered unless
personnel are entering or exiting the work platform.
ALWAYS keep personnel and obstructions clear of
the machine when repositioning boom or basket.
Minimum Safe Approach Distance
Voltage Range
(Phase to Phase)
(Feet) (Meters)
0 to 300V Avoid Contact
Over 300V to 50KV 10 3.05
Over 50KV to 200KV 15 4.60
Over 200KV to 350KV 20 6.10
Over 350KV to 500KV 25 7.62
Over 500KV to 750KV 35 10.67
Over 750KV to 1000KV 45 13.72