User's Manual
UM600410 Rev C page 65 of 81
User Manual –I-Series 4.0
General-purpose Input/Output (GPIO) Support
The I-Series 4.0 supports a GPIO which can be used to connect to peripherals such as a motion sensor.
Elo has an optional GPIO cable (PN: E211544) with flying leads so that it is easy for users to connect their
own peripherals.
Pinout of the GPIO cable (PN: E086398):
Red Wire: Pin 1 → 5 Volt output connection
White Wire: Pin 2 → Input connection 1
Green Wire: Pin 3 → Input connection 2
Two Black Wires: Pin 4 and Pin 5 are tied to ground
5V, 200mA is the max voltage and current available via this GPIO port.
G-Sensor
All I-Series 4.0 units are equipped with a g-sensor and will rotate the video based on the orientation of the device.
USB – C Settings
All I-Series 4.0 device supports USB – C video, audio and touch via the USB- C cable.
The 15.6 and 22in I-Series 4.0 device can also support power up to an Elo 1502L Touch monitor via the USB – C cable when using the optional Elo 90W
power supply.
To enable video output, enter the developer options and click on USB and DP configuration.
• Default mode is DP (4 lanes) & HS-USB (allows for video output and USB2.0 speeds)
• Note Ethernet speeds will be limited to USB2.0 speeds
• User can change to SS-USB only to allow for higher USB and Ethernet speeds. There is no video output in this mode.
• If the USB protocol is changed, please reset the I-Series Device.