User's Manual

7
Japan
All components of the cord set (cord, connector, and plug)
must bear a “PSE” mark and registration number in
accordance with the Japanese Dentori Law.
The minimum specifications for the flexible cord are: (1) 0.75
mm
2
conductors, (2) Type VCT or VCTF, and (3) 3-conductor.
The cord set must have minimum rated current capacity of 7 A.
The attachment plug must be a two-pole, grounded type with a
Japanese Industrial Standard C8303 (15 A, 125 VAC)
configuration.
Other Countries
The cord set fittings must bear the certification mark of the
agency responsible for evaluation in a specific country.
Acceptable agencies are:
CCC (China)
The flexible cord must be of a HAR (harmonized) type HO5VV-
F 3-conductor cord with a minimum conductor size of 0.03
square inches.
The minimum specification for the flexible cord for Class II
product are: (1) 2X0.75 mm
2
conductors, (2) 2-conductor cord.
The cord set must have a current capacity of at least 10 A and
a nominal voltage rating of 125 / 250 VAC.
This model IS DESIGNED TO USE WITH
THE FOLLOWING AC ADAPTER MODEL ONLY
Manufacture: LI SHIN INTERNATIONAL ENTERPRISE CORP.
Manufacture: Delta
Battery Pack Safety
The battery pack is intended to use only with this notebook.
The battery pack is not replaceable by the end user. Only
qualified service technicians should replace the battery pack.
Do not disassemble the pack.
Do not dispose of the battery pack in fire or water.
To avoid risk of fire, burns, or damage to your battery pack, do
not allow a metal object to touch the battery contacts.