Welcome... to your new Motorola Baby Monitor! Thank you for purchasing the MBP27T, MBP27T/2, MBP27T/3, MBP27T/4. Now you can see and hear your baby sleeping in another room or you can monitor your older children in their playroom. Please retain your original dated sales receipt for your records. For warranty service of your Motorola product, you will need to provide a copy of your dated sales receipt to confirm warranty status. Registration is not required for warranty coverage.
Overview of the Parent Unit 11 12 10 19 1 18 POWER 13 3 2 9 4 8 7 6 3. 4. 5. 6. 7. 8. 14 5 16 1. 2. 15 17 Display (LCD screen) Object temperature mode Press and hold to measure the liquid temperature Forehead temperature mode Press and hold to measure the body temperature at forehead Scroll Up/Volume+ Button Scroll Down/Volume- Button Return/Switch Camera Button Press to return to previous menu level. Press to switch camera units (if paired with more than one camera).
Overview of Your Baby Unit 1 2 5 9 4 7 8 1. Photo Sensor (Night Vision Mode) 2. Camera Lens 3. Infrared LEDs 4. Power LED 5. ON/OFF Switch 3 6 6. Power Adapter Socket 7. Pair Key 8. Microphone 9. Speaker Important guidelines for installing your Baby Monitor • To use your Video Monitor Baby and Parent Units together, you must be able to establish a radio link between them, and the range may be effected by environmental conditions.
1. 2. Safety Instructions ..................................................................................... 6 Getting Started.......................................................................................... 8 2.1 2.2 2.3 2.4 3. Using the Baby Monitor........................................................................... 12 3.1 3.2 3.3 3.4 3.5 4. Setting up................................................................................................... 12 Night Vision Mode............
1. Safety Instructions WARNING: STRANGULATION HAZARD - Keep the unit and adapter cords more than 3 feet from the crib and out of baby’s reach. NEVER place camera or cords within the crib. SECURE the cord. Never use extension cords with AC Adapters. Only use the AC Adapters provided. CAMERA SET UP & USE: ● Determine a location for the BABY UNIT that will provide the best view of your baby in his/her crib.
ENGLISH • Do not install the baby monitor in extreme cold or heat, direct sunlight, or close to a heat source. • Only use the chargers and power adapters provided. Do not use other chargers or power adapters as this may damage the device and battery pack. • Only insert a battery pack of the same type. • Do not touch the plug contacts with sharp or metal objects. • Connect the power adapters to easily accessible mains sockets. CAUTION Risk of explosion if battery is replaced by an incorrect type.
2. Getting Started 2.1 1. Baby Unit Power Supply Connect the small plug of the power adapter to the Baby Unit (camera) and the other end to the electrical outlet. NOTE Only use the enclosed power adapter (6V DC / 500mA) with the slightly larger DC plug. 2. 3. 2.2 Slide the ON/OFF switch to the ON position. The power LED will light up in orange. Slide the ON/OFF switch to the OFF position to turn the Baby Unit off.
2. Place the battery cover over the compartment and gently tighten the screw in a clockwise direction using a Small cross head or Flat end screwdriver. Parent Unit Power Supply POWER 2.3 ENGLISH Small cross head or Flat end screwdriver. IMPORTANT Installing the rechargeable battery pack and charge it fully before use is recommended. This will allow the unit to operate on battery in the event of a power failure, or when moving to a different room. 1. 2. 3.
4. 5. If there is no connection or you are out of range, the video display will go off and the symbol will flash on the LCD display, and the unit will beep every 9 seconds. (If the unit is on scan the 1 ? symbol displays.) Move the Parent Unit closer to the Baby Unit the link is re-established. Press and hold the P POWER ON/OFF button, until the progress bar scrolls fully across, to turn OFF the Parent Unit.
Registration (Pairing) The Baby Monitor Camera is pre-registered to your Parent Unit. You do not need to register it again unless the Baby Unit loses its link with the Parent Unit. To re-register your Baby Unit, or register a new Baby Unit, follow the procedure below: 1. 2. 3. Press the button of the Parent Unit and then press the - DOWN button to select the Camera setting icon , and press the button to enter. Press the - DOWN button to select ADD CAMERA icon , and press the button to confirm.
3. Using the Baby Monitor 3.1 Setting up • Place the Baby Unit in a convenient location (e.g. on a table) and point the camera lens towards the area you want to monitor. • Adjust the Baby Unit's head angle by rotating the camera up, down, left and right until you are satisfied with the image in the Parent Unit.
Forehead Temperature Mode • Always make sure the probe lens is clean without any, damage free and the forehead is clean. • Place the probe tip about 1 cm away from the central forehead Figure 1 of the baby (Fig. 1) • Press and hold the Forehead Temperature button until you hear the beep and the reading displays on the LCD screen. Note: a. Temperature Measurement Range: Forehead temperature mode: 32~42.2°C (89.6~108°F) b. Forehead temperature is displayed in oral mode.
4. Parent Unit Menu Options 4.1 1. 4.2 1. 2. 3. 4. 4.3 1. 2. 4.4 1. 2. 3. 14 Volume While in monitor mode, press the + UP button or - DOWN button to select the desired volume level from level 1 ~ 8. (The default volume level setting is level 4.) Brightness Press the button and the first menu option will appear. To select the BRIGHTNESS icon press the button. Press the + UP button or - DOWN button to select the desired brightness level from level 1 ~ 8. (The default brightness level setting is level 4.
Camera Control 4.5.1 1. 2. 3. 4. ENGLISH 4.5 Add (pair) a camera Press the button and the first menu option will appear. Press the - DOWN button to select the Camera setting icon , and press the button to enter. Press the - DOWN button to select ADD CAMERA icon and press the button to confirm. 1 / 2 / 3 / 4 will pop up, press the + UP button or - DOWN button to select the desired Camera identification number, and press the button to start searching for a camera unit.
4.5.3 1. 2. 3. 4. Delete a camera Press the button and the first menu option will appear. Press the - DOWN button to select the Camera setting icon , and press the button to enter. Press the - DOWN button to select DELETE CAMERA icon and press the button to confirm. 1 / 2 / 3 / 4 will pop up, press the + UP button or - DOWN button to select the desired Camera unit, press the button then press the DOWN button to select the DELETE CAM icon .
1. 2. 3. 4.7 1. 2. 3. 4. Body Temperature Measurement Review ENGLISH 4.6 Press the button and the first menu option will appear. Press the - DOWN button to show the record icon and press button to confirm. Press - button to review previous measurement record (body temperature only). Change of Measurement Scale Press the button and the first menu option will appear. Press the - DOWN button to show the Thermometer icon button to confirm. Press the button to show the C/F selection icon °C and °F.
5. Disposal of The Device (environment) At the end of the product lifecycle, you should not dispose of this product with normal household waste. Take this product to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, user's guide and/or box indicates this. Some of the product materials can be reused if you take them to a recycling point.
Clean the MBP27T, MBP27T/2, MBP27T/3, MBP27T/4 with a slightly damp cloth or with an anti-static cloth. Never use cleaning agents or abrasive solvents. Cleaning and care • Do not clean any part of the product with thinners or other solvents and chemicals – this may cause permanent damage to the product which is not covered by the warranty. • Please make sure the probe is clean to ensure an accurate reading. • The probe tip is the most delicate part of the thermometer.
7. Help Display No display • Try recharging or replacing the battery pack. • Reset the units. Disconnect the battery pack of the Parent Unit and unplug both the units' electrical power, then plug them back in. • Is the unit turned on? Press and hold the ON/OFF button P on the Parent Unit to turn it ON. • Is the correct camera selected? Change the camera number, if necessary. • Is the video display turned on? Press the VIDEO ON/OFF button V to turn it on.
Noise interference on your Parent Unit • Your Baby and Parent Units may be too close. Move them farther apart. • Make sure there is at least 3 to 4.5 feet (1 to 1.5 meters) between the 2 units to avoid audio feedback. • lf the Baby Unit is too far away it may be out of range, try moving the Baby Unit closer to the Parent Unit. • Make sure the Baby and Parent Units are not near other electrical equipment, such as a television, computer or cordless/mobile telephone. • Use of other 2.
8. General Information lf your product is not working properly.... 1. Read this User's Guide or the Quick Start Guide. 2. Contact Customer Service: US and Canada 1-888-331-3383 Email: motorola@encompass.com To order a replacement battery pack, contact customer service. Consumer Products and Accessories Limited Warranty ("Warranty") Thank you for purchasing this Motorola branded product manufactured under license by Binatone Electronics International LTD ("BINATONE").
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE THE REPAIR OR REPLACEMENT PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
Products Covered Consumer Products Length of Coverage One (1) year from the date of the products original purchase by the first consumer purchaser of the product. Consumer Accessories Ninety (90) days from the date of the accessories original purchase by the first consumer purchaser of the product. Consumer Products and Accessories The balance of the original warranty or that are Repaired or Replaced for Ninety (90) days from the date returned to the consumer, whichever is longer.
ENGLISH Altered Products. Products or Accessories with (a) serial numbers or date tags that have been removed, altered or obliterated; (b) broken seals or that show evidence of tampering; (c) mismatched board serial numbers; or (d) nonconforming or non-Motorola branded housings, or parts, are excluded from coverage. Communication Services.
FCC and IC regulations FCC Part l5 NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Changes or modifications, to this equipment not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. The socket-outlet shall be installed neat the equipment and shall be easily accessible.
Technical Specifications Baby unit Frequency 2.4 GHz to 2.48 GHz Image sensor color CMOS 0.3M Pixels Lens f 2.5mm, F 2.4 IR LED 8 pcs Power Adapter: 5E-AD 060050-U; Input: 100-240V, 50/60Hz 300mA; Output: 6V, 500mA OR Adapter: BLJ5W060050P; Input: 100-240V, 50/60Hz 150mA; Output: 6V, 500mA WARNING Use only with provided power supply.
Frequency 2.4 GHz to 2.48 GHz Display 2.4" diagonal Display colors 16M color LCD Brightness control 8 steps Volume control 8 steps Power Adapter: 5E-AD 060050-U; Input: 100-240V, 50/60Hz 150mA; Output: 6V, 500mA ENGLISH Parent unit OR Adapter: BLJ5W060050P; Input: 100-240V, 50/60Hz 150mA; Output: 6V, 500mA WARNING Use only with provided power supply. OR Battery: Model - JUSTHIGH Ni-MH AAA 3 x 1.
Accuracy Forehead mode: ±0.5°F (0.3°C). This thermometer converts the forehead temperature to display its "oral equivalent." Surface mode: ±0.5°F (0.3°C) within 71.6~108°F (22~42.2°C), others ±4% or ±4°F (2°C) whichever is greater Enclosure rating IP22 Compliance Comply with ASTM E1965-98, IEC/EN60601-12(EMC), IEC/EN60601-1(Safety) standards. Note Keep the device away from hot or boiling water and chemicals. There is no gender and age limitation for using the infrared thermometer.
Manufactured, distributed or sold by Binatone Electronics International LTD., official licensee for this product. MOTOROLA and the Stylized M Logo, are trademarks or registered trademarks of Motorola Trademark Holdings, LLC. and are used under license. All other trademarks are the property of their respective owners. © 2013 Motorola Mobility LLC. All rights reserved. Version 5.