Instruction manual

Recording settings (User level: ID3)
26 English
It allows you to set HDD recording area management conditions
such as overwrite recording, remaining disk warning level,
automatic erase function, etc.
1 OVERWRITE (Initial setting: ON)
Setting recording conditions to overwrite for the normal and
alarm recording areas.
ON:
When the hard disk becomes full, recording continues and
data is automatically overwritten from the first images.
The [AREA FULL RESET] button of the normal or alarm
recording area does not appear on the RECORDING AREA
SET screen.
OFF:
The remaining capacity warning indicator of the DVR starts
blinking when the recording area becomes full, recording
stops.
2 REMAINING DISK WARNING
The remaining disk warning buzzer can be programed to go off
when the remaining space available reaches a specified value
if the [OVERWRITE] setting is set to "OFF" for the normal and
alarm recording area.
Now, setting the remaining disk warning level that will set the
warning buzzer on. The set level will apply to both the normal
and alarm recording areas.
Available settings: 1 - 10%
3 SERIES REC (Initial setting: OFF)
Series recording can be set if the multiple DVR units are
connected using the SERIES REC terminal at the rear panels.
Series recording implies that recording can automatically
continue on the next DVR unit when the recording area of the
first DVR becomes full.
ON: Performing series recording.
OFF: Series recording is not activated.
4 AUTO DELETE (Initial setting: OFF)
It is the automatic erase function of the images saved in the
normal and alarm recording area. The image data that is older
than the specified storage period are automatically erased.
Selections: OFF, 1, 2, 3 ... 99 DAYS
1 - 99 DAYS: To set the auto delete function and storage
period between 1 and 99 days.
OFF: The images will not be erased automatically.
B
RECORDING CONDITIONS SET
By setting [OVERWRITE] to "ON" when recording
for a long time and the recording area becomes full,
the data will be overwritten and erased sequentially
from the oldest images. Save necessary images
before they are overwritten.
When the [OVERWRITE] setting of the normal and
alarm recording area is set to "ON","***" is
displayed, the remaining disk warning level cannot
be set.
2
3
4
1
Series recording is only available when
[OVERWRITE] is set to "OFF".
The auto delete function does not apply to the
archive area.
If you use the auto delete function, copy or
download important data before the storage
period expires. (Refer to P18, 19)