Operating instructions

Error Messages
Message Meaning Possible cause
SmartDrive
Limp modeCheck Remedy
Short circuit/broken cable in wiring for
pump valves
Check wiring to pump valves
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Solenoid valve defective Replace the solenoid valve
The charge pressure is too low Check charge pressure and replace
supply pressure valve if necessary (30+/-
3 bar)
The drive pump 1 is defective Replace the drive pump 1
Internal SmartDrive error Replace SmartDrive
Short circuit/broken cable in wiring for
pump valves
Check wiring to pump valves
30 SmartDrive pump
1 control loop
Error: Control loop drive
pump 1 front axle
31 SmartDrive pump
2 control loop
Error: Control loop drive
pump 2 rear axle
pump valves
Valve plug defective Replace valve plug
Coil for solenoid valves defective Replace coil
Solenoid valve defective Replace the solenoid valve
The charge pressure is too low Check charge pressure and replace
supply pressure valve if necessary (30+/-
3 bar)
The drive pump 2 is defective Replace the drive pump 2
Internal SmartDrive error Replace SmartDrive
2 control loop
pump 2 rear axle