CAUTION BEFORE INSTALLATION
儜Do not plug in before installation.
儜
I f you need an electric power system or extension, please consult a qualified electrician.
儜Please contact our service center(847-458-2334) when you want to reinstall the bidet
product(move or replacement).
STEPS
儜Shut off the water supply shut off valve.
儜Drain the toilet tank completely.
儜Then remove the existing fill valve water supply hose.
Flexible Tube
Water supply hose
(for toilet flush water tank)
1
Connect T-Valve.
儜Remove existing supply hose connected to the toilet tank.
Make sure not to damage the water supply hose
儜
Install T-Valve at the thread from tank.
儜Remove existing supply tube from fresh tank
儜If your shut off valve is
1/2"
O.D compression size,
use supplied
1/2"
conversion nut as shown below.
2
Removing the existing seat and lid.
儜Remove mounting bolts to release existing
toilet seat from toilet.
Ú Check for any water leaks.
3
Connect the water supply hose to the
assembled T-valve.
4
1/2" O.D.Comp. conversion
nut with packing
Turn Off Water.
6
Installation
X^XXWYiiTX^WWSYWWWG|zlyNGthu|hsUGGGX_ YWX^TXXTWZGGG㝘㤸GXXaY_aXY
INSTALLATION
Installation Manual and Operating Instructions
19
Ú Check for any water leaks.
Catch plate
Place the plate and guides over each mounting hole.
Insert the mounting bolts through the plate and
mounting holes.
5
1. Slide this product onto the catch plate
centering the unit with the guide arrows on the Base.
2. You will hear a click once this product is securely
mounted to the catch plate.
3. This product will feel a little loose on the toilet bowl.
Adjust the fit from front to back and side to side for balance.
4. Tighten the nuts on both bolts securely.
7
Check for any water leaks.
Ú Customers should use the new hose set provided
with the product. Do not use used set again.
8
Slide cone packing and washers onto the bolts
then fasten to securely mount bidet seat to toilet.
6
Installation Catch Plate. Bolt and Nut Assembly.
Assembly. Connect the flexible tube from side of
T-Valve to this product,
Open the Angle Stop valve to fill water.
Cone Packing
Nut
Bolt Case
Bolt
Central mounting
groove
Bolt
BACK
L-Valve
X^XXWYiiTX^WWSYWWWG|zlyNGthu|hsUGGGX` YWX^TXXTWZGGG㝘㤸GXXaY_aXY