User manual PRD 6540002A RFID 134.2 KHz fixed reader Date Version RFID 134.2 KHZ fixed reader (PRD 6540002A) User Manual Manufacturing Site: 1 Commander Robert MALRAIT Street ZA des Granges BP 30303 27303 BERNAY CEDEX France Tel: +33(0)2 32 47 83 40 Fax: +33(0)2 32 47 83 50 Web: www.biolog-animal.com UM-PRD 6540002A RFID 134.2Khz Fixed Reader-V1.0.docx 05/03/2020 Page 1 / 14 V1.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 2 / 14 Summary 1. General information to the user. .................................................................................................3 1.1. 1.2. 1.3. 1.4. 2. 3. 4. Introducing the reader .................................................................................................................4 Starting the drive ................................................................................
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 3 / 14 This document gives information on how to use the RFID fixed reader works. 1. General information to the user. 1.1. Manual function. Please read this user manual carefully and in its entirety before using the equipment. This user manual provides you with clear and detailed information on how to use the fixed RFID reader. The illustrations and pictures in this manual represent all fixed RFID readers models.
Date User manual PRD 6540002A RFID 134.2 KHz fixed reader 05/03/2020 Version Page 4 / 14 2. Introducing the reader 1 red light: Power ON indicator 6 keys: - READ key - TOP key - LEFT key - MENU / VALIDATION key - RIGHT key - BOTTOM key 1 USB output cable UM-PRD 6540002A RFID 134.2Khz Fixed Reader-V1.0.docx Alphanumeric display: 2 16-character lines 1 green light: OK status indicator 1 external power supply Input: 100 - 240VAC Output: 7.5 VDC - 3A V1.
Date User manual PRD 6540002A RFID 134.2 KHz fixed reader 05/03/2020 Version V1.0 Page 5 / 14 3. Starting the drive The reader is powered by plugging the external power cord into the electrical plug. The voltage range of entry is between 100 and 240VAC.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 6 / 14 In standby mode: - the reader no longer detects RFID. - the display and the red light turn out. - only the READ button remains active, the other keys are no longer active. - consumption is maintain to a minimum. To turn the reader back on, press the READ button. 5. Reader settings Press the MENU button The reader displays: to enter the setting menu.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 7 / 14 Press the keys to increase or decrease the value of the desired duration. You can select a viewing time comprised between 1 and 300 seconds. Press the MENU button Press the keys to validate your selection, the digital screen then displays: to enter whether or not you want to confirm your choice.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 8 / 14 Shows the current menu Time to manage dual readings in progress Press the keys to increase or decrease the desired duration. You can choose a display time-of between 1 and 30 seconds. Press the MENU button Press the keys to validate your selection, the digital screen then displays: to enter whether or not you want to confirm your choice.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 9 / 14 If no button is activated for 30 seconds, the digital screen returns to the setting menu. 5.6. Menu "UPDATE FIRMWARE" This update is to be performed following instructions sent by BIOLOG-id. Before selecting this menu, make sure: - to install the"PSoC5 Firmware Updater" application on a computer. - to have a USB link between the PRD654 drive and the computer.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 10 / 14 Click on the arrow to open the drop-down menu "Liste des firmwares disponibles" Click"Import"and then search the directory for the update file type "PRD6540002-F02-V1.00-250220.cyacd". Then click "Ouvrir" and the file name appears: During the USB connection, the PORT COM service is used. You can identify the COM port number used in your computer's device manager.
Date User manual PRD 6540002A RFID 134.2 KHz fixed reader Wait about 2 minutes until the progress bar is solid. The update is complete when the meter is at N-1 and the reader has started well. Then click "Déconnecter" The drive firmware is updated and the main menu is activated. USB communication settings Serial communication on the USB port has the following parameters: Settings Baud Rate Parity Data Bits Stop Bits Flow control UM-PRD 6540002A RFID 134.2Khz Fixed Reader-V1.0.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 12 / 14 5.7. Find the reader's communication port Once the reader is connected to the computer, to find out which communication port the computer is connected to, open the computer's device manager. On this page, the reader must appear under the name "USB Serial Port" followed by the assigned communication port number. In the example Port COM 3.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 13 / 14 6. Safety guidelines 6.1. General safety guidelines Ensure that the power cable is not jammed or bent when installing or moving the reader. Do not disassemble or disable the elements of the PRD_6540002A reader. Do not place an object on the PRD_6540002A reader.
User manual PRD 6540002A RFID 134.2 KHz fixed reader Date 05/03/2020 Version V1.0 Page 14 / 14 6.3. Contraindications As a preventive measure, people with pacemakers are advised not to use PRD 654 0002A reader. 6.4. Warning for United States users Federal Communication Commission Interference Statement 47 CFR Section 15.105 (b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.