User's Manual
Table Of Contents
- CHAPTER 1 - INTRODUCTION
- CHAPTER 2 - PLANNING THE INSTALLATION
- CHAPTER OVERVIEW
- 2.1 PLANNING THE INSTALLATION
- 2.1.1 RECOMENDED STEPS FOR A SUCCESSFUL INSTALLATION
- 2.1.2 REQUIREMENTS
- 2.1.3 UNPACK EQUIPMENT
- 2.1.4 CHOOSING THE INSTALL LOCATION
- 2.1.5 PLAN DEVICE NETWORK
- 2.1.6 CHOOSE NETWORK TYPE
- 2.1.7 CHOOSE POWER SOURCE
- CHAPTER 3 - INSTALL SOFTWARE
- CHAPTER OVERVIEW
- 3.1 SECUREADMIN LITE SERVER
- Figure 3-1 Install Menu
- Figure 3-2 SecureAdmin Lite Server Installation Wizard
- Figure 3-3 SecureAdmin Lite Server License Agreement
- Figure 3-4 SecureAdmin Lite Server Choose Destination Location
- Figure 3-5 Database Selection
- Figure 3-6 Connecting to SQL Server option
- 3.1.1 REPAIRING AN INSTALLATION OF SECUREADMIN LITE SERVER
- 3.1.2 UNINSTALLING SECUREADMIN LITE SERVER
- 3.1.3 UPGRADING AN INSTALLATION OF SECUREADMIN LITE SERVER
- 3.2 SECUREADMIN LITE CLIENT
- Figure 3-9 Menu
- Figure 3-10 InstallShield Wizard
- Figure 3-11 Welcome Screen
- Figure 3-12 SecureAdmin Lite Client License Agreement
- Figure 3-13 SecureAdmin Lite Client Choose Destination Location
- Figure 3-14 Fingerprint Placement Feedback Option Selection
- Figure 3-15 InstallShield Wizard Finished
- 3.2.1 MODIFYING AN INSTALLATION OF SECUREADMIN LITE CLIENT
- 3.2.2 REPAIRING AN INSTALLATION OF SECUREADMIN LITE CLIENT
- 3.2.3 UNINSTALLING SECUREADMIN LITE CLIENT
- 3.2.4 UPGRADING AN INSTALLATION OF SECUREADMIN LITE CLIENT
- CHAPTER 4 - INSTALL HARDWARE
- CHAPTER 5 - SYSTEM START-UP PROCEDURES
- CHAPTER 6 - CONFIGURE DEVICE
- CHAPTER 7 - MAINTENANCE AND CLEANING
- CHAPTER 8 - TROUBLESHOOTING
- CHAPTER OVERVIEW
- 8.1 INSTALLATION ERROR MESSAGES
- CHAPTER 9 - NOTICES
- GLOSSARY
Part # 430-4G-050-00-004
© 2011 - L-1 Identity Solutions Inc. All rights reserved
Install Hardware
Source
Voltage
1 2 3 4 5 6 7 8
Load
Voltage
DC Load
Connector
IEEE 802.3af
using spare
pairs
48 V DC,
protected
RX RX TX DC+ DC+ TX DC- DC- (embedded)
Industry
Standard
for
embedded
PoE
Figure 4-8 RJ45 Pin Location
4.6 CONNECT DEVICE TO NETWORK
The 4G Lite devices support RS-485, Ethernet 10baseT and 100baseTX protocols.
4.6.1 ETHERNET NETWORK CONNECTIONS
Ethernet connections to the device are made through a standard RJ-45 connector on the
back of the device.
4.6.2 RS-485 NETWORK CONNECTIONS
To connect a device to an RS-485 network, connect the appropriate wires to the provided
pigtail in accordance with the pin-out diagram.