3-pin Mini Connector
(Pin 3 is Earth Ground)
The device's ground connection must be properly connected to avoid damage by Electro-Static
Discharge (ESD).
To connect the device to earth ground, connect Pin 3 of the mini connector (located on the rear
of the device) to earth ground. This terminal should not be connected to the neutral, to the cable
shield, or to any other wire except earth ground. See Figure 4-5, below. The connection to earth
ground should use the largest wire possible (12 AWG) and be as close to the termination point
(water pipe, etc.) as possible.
Power
Power
Earth Ground
4.5. CONNECT DEVICE TO EARTH GROUND
Figure 4-5: Earth Ground Connection