User's Manual

Install Hardware
Part No. 430-4G-200-00-000
© 2009, L-1 Identity Solutions Inc.
4-12
After rebooting, check for a "Wireless" icon on the device's LCD. Press the Left arrow
key to display Wireless info. If wireless operation is set up correctly, pertinent wireless
network information is displayed. If no information is displayed, then the wireless setup
is not set correctly.
SecureAdmin can scan for and auto-detect wireless devices. If you want to use
SecureAdmin to scan for wireless devices, ensure that the "multicasting" option is
enabled in your router.
The maximum recommended distance from an access point is 25 feet.
NOTICE
The V-Station 4G and V-Flex 4G devices incorporate an internal relay that enables them to op-
erate a deadbolt/door strike directly.
4.8. C
ONNECT DEVICE TO DOOR
The snubber diode and DC power supply for the deadbolt/door strike are not
supplied with the V-Station 4G and V-Flex 4G devices. The power supply
should be specified in accordance with the voltage and current requirements
of the deadbolt/door strike, but it must be ensured that the current to operate
the deadbolt/door strike does not exceed 170 mA.
CAUTION
Assuming the current drawn by the deadbolt/door strike is less than 170 mA, the connections
between the V-Station 4G or V-Flex 4G device, deadbolt/door strike, and power supply for the
deadbolt/door strike should be made as shown in Figure 4-12 (on the next page). Note that a
snubber diode (1N4007 or equivalent) must be connected across the deadbolt/door strike to
protect the DC power supply from inductive kickback.
If the current required to operate the deadbolt/door strike exceeds 170 mA, an external relay
must be used in conjunction with the V-Station 4G or V-Flex 4G device. The external relay must
be specified so that its contacts are rated to carry the current required by the deadbolt/door
strike, and that the current required to operate its energizing coil is within the 170 mA capacity
of the V-Station 4G or V-Flex 4G device's internal relay.
The internal relay is limited to a maximum current of 170 mA. If the deadbolt/
doorstrike to be controlled draws more than 170 mA, damage to the device
may occur. If the deadbolt/door strike load exceeds 170 mA, an external re-
lay must be used, as described below.
Do not use the same power supply to power a V-Series 4G device and a
door strike.
WARNING