User's Manual

Install Hardware
Part No. 430-4G-200-00-000
© 2009, L-1 Identity Solutions Inc.
4-13
Figure 4-12: Connections for Internal Relay Operation
The power supply for the external relay must be chosen to match the operating voltage and cur-
rent of the external relay coil, but its voltage must not exceed the V-Station 4G or V-Flex 4G de-
vice's internal relay maximum voltage rating of 250 volts.
The external relay should be connected in accordance with Figure 4-13 below. Note that snub-
ber diodes (1N2007 or equivalent) should be connected across the external relay coil and the
deadbolt/door strike.
V-Station 4G or V-Flex 4G
Deadbolt/Door
strike
Max load 170 mA
27 - N.O. (Normally Open)
28 - Common
COM N.O. N.C.
Deadbolt/Door Strike
Con 1 Con 2
DC Power Supply
-DC +DC
Snubber Diode
1N4007
27 - N.O. (Normally Open)
28 - Common
V-Station 4G or V-Flex 4G
External
Relay Coil
+
DC Power Supply
for External Relay
External Relay Contacts
External
Relay
Snubber
Diode
Figure 4-13: Connections for External Relay Operation