1.2.9 SAFETY PRECAUTIONS
Below are safety precautions that should be observed when operating or installing a
device.
1.2.9.1 ELECTRO-STATIC DISCHARGE
L-1 Identity Solutions recommends that Administrators inform Users of these points
during the enrollment process:
Always use the Ridge-Lock to position a finger *before* touching the
sensor.
Always stand on the ESD-dissipative floor covering (if installed).
Do not touch other people or objects when touching the sensor.
Always maintain at least 12 inches of space around yourself when
touching the sensor.
Do not allow articles of clothing to touch the sensor.
L-1 Identity Solutions recommends that Installers always follow these points (in addition
to the points listed above):
When installing or working on a unit, always use a grounding wrist-
strap that is connected to a quality Earth ground.
Check the device's cabling for ground faults.
Ensure that the device's ground connection (located on the rear of the
device) is connected to a quality Earth Ground.
1.2.9.2 DEVICE HANDLING GUIDELINES
Do not install the device in locations where the device would be
exposed to direct sunlight, high levels of relative humidity, particulate
matter, or flammable vapors.
Do not install the device near radiators or other heat sources.
Do not allow magnetic objects to come within close proximity to the
device.
Strong magnetic fields might damage the device.
Do not let liquids Card the device.