With the wall mounting plate mounted and the device secured to the mounting plate, the
tamper switch is depressed, closing the electrical circuit. When the device is removed
from the wall by removing the security screws or in the event that the device is removed
from the wall by force, the tamper switch opens.
To access the tamper-protection setting on the V-Station 4G device using the keypad:
Enter the Admin menu on the device by pressing the Left arrow and Enter keys
simultaneously.
Key in the Admin password (default is "0000") and press OK.
Select the System icon and press OK.
Select Device Settings and press OK.
Select SDC/Tamper Settings and press OK.
Select Tamper Settings and press OK.
If the alarm has sounded, select Clear and Re-enable. The Tamper protection setting is
set to disabled by default.
7.1.1.2 REPLACING THE SENSOR
WARNING
The sensors can only be replaced with the same type as previously
used. L-1 EAS does not support changing the type of sensor.
Different types of sensors are not interchangeable, and the device
will fail to operate.
NOTICE
Power to the device MUST BE DISCONNECTED prior to
servicing.
If the device is secured to the wall please be sure to follow the
Disable instructions.
Tamper settings prior to the removal of the device from the
wall.
ESD protective handling procedures must be followed before
any service is applied to the device.