User's Manual

October152009InstallationGuideDraftEditPurposesOnly Page49
Installation Guide – October 2009 – Edit Purposes Only
2009
9 8 #8x1" thread forming screw, pan head, Philips
9 8 wall mount anchor, conical, for #8 screws
4.1.4 ATTACH DEVICE TO MOUNTING PLATE
4.1.4.1 4G V-STATION AND V-FLEX INDOOR DEVICES
Once all the electrical connections have been made to the device, it can be attached to
the mounting plate as follows:
For the V-Flex 4G, insert the four hooked protrusions on the rear of the device into the
corresponding slots on the mounting plate. Hold the device against the plate and gently
press it in a downward direction to engage the hooks. Insert the star-shaped screw at
the bottom center of the mounting plate and tighten with the wrench provided. Do not
over-tighten.
For the V-Station 4G, hold the device with the top slightly tilted toward you, at about a
30-degree angle to the wall. Hold the bottom of the device against the mounting plate
and lower it so that the two hooks on the bottom of the mounting plate engage the
corresponding slots on the device. When the hooks are properly engaged, the top of the
device can be pivoted up against the mounting plate. It will drop down slightly, locking
itself in the closed position, and should be secured in this position with the star-shaped
screws in the holes at the right and left ends on the bottom of the device. Do not over-
tighten.
With the securing screws removed, the V-Station 4G device can be pivoted down 90
degrees from the wall, to allow access for making connections, etc. The device can be
removed from the mounting plate by tilting it at an angle approximately 30 degrees to
the wall and gently lifting it up off the hooks on the mounting plate.
Figure 4-6 Device Open for Installation or Service
4.1.4.2 4G EXTREME DEVICES
TBD