LED T ABLE S ETTINGS
71
© Copyright 2002, Bioscrypt Inc. All rights reserved.
Figure 32: LED Table Settings
LED Table Settings
Choosing the LED Table Settings menu item will allow the user to define
how the reader’s LED will function under specific operations. Selecting
this option will display the dialog shown in figure 30. The dropdown
selection box chooses the function (enroll, verify, idle, etc.) to modify.
Below that is each possible state for the selected operation. Line 1
represents GREEN LED, Line 2 represents RED LED, and Line 3
represents the Buzzer.
In the example shown, the ENROLL
function is chosen. The first two states are
disabled since they have no meaning
for the ENROLL function.
Both Line 1 and Line 2 are chosen to
indicate PLACE FINGER. This will turn
GREEN and RED LEDs on creating a
YELLOW LED.
The REMOVE FINGER operation is
signaled by clearing all LEDs, thus
making the LED turn off.
If a FINGER NOT DETECTED
happens, then the RED LED is shown
for 600 milliseconds.
A PASS is indicated by both turning the
LED GREEN and sounding the
BUZZER for 600 milliseconds.
To indicate a FLASHING LED, choose
the duration and set the INTERVAL
time (1350 is normal).
Figure 33: LED Table Settings
The USE TABLE checkbox indicates whether to use these setting for non-Wiegand
initiated commands (like commands coming from PC). Repeat process of other functions
then press the ACCEPT to transfer to the current unit. If the ACCEPT is not pressed, the
changes are ignored.