S ENSOR C ONFIGURATION
72
© Copyright 2002, Bioscrypt Inc. All rights reserved.
Sensor Configuration
Note: This feature has been disabled in recent versions of
VeriAdmin, including v4.3
Choosing the Sensor Configuration menu item will allow the reader’s
sensor settings to be altered. It is recommended that only advanced
users attempt to modify these settings since they can drastically affect
the fingerprint reader’s performance. Please call Bioscrypt Technical
Support with any questions before attempting modifications.
The Bioscrypt sensor needs to be
calibrated for optimal performance.
For Veridicom Sensors:
To perform this task the user should place their
finger on the sensor of the reader identified by
the current Communication settings. Next, press
the CALIBRATE button and hold the finger
steady until the progress bar completes. The
new values will be displayed and the VeriAdmin
software will ask if you want to see a test image.
With the finger still on the sensor, select YES. An
image will be scanned and displayed. If the
image looks good, choose YES to accept the new
values.
For Authentec Sensors:
To perform this task the user should NOT place
their finger on the sensor of the reader. Press the
CALIBRATE button.
The TEST IMAGE button will scan and display
a fingerprint image.
Figure 35: Sensor Configuration
NOTE: A Network ID of –1 is
NOT valid for these operations