Update Firmware
Choosing the Update Firmware menu item will
allow the reader’s DSP firmware to be field-
updated. Also, for V-Smart units, the external
storage device (ESI) can also be programmed
in the field. It is recommended that only
advanced users attempt to perform this
operation. Please call Bioscrypt Technical
Support with any questions.
Figure 36: Update Firmware Menu
Option
Choosing this option will begin the
Update Firmware Wizard. Follow the
steps and choose the correct firmware
file. This process can take between 1-10
minutes depending on the current baud
rate settings.
NOTE: Before attempting this operation,
make sure the current communication
settings are correct and that the PC and
reader are communicating properly. It is
recommended that the HELP, ABOUT VERIADMIN menu option is used both before and after
this operation to ensure the firmware version changed. Depending on the prior version,
downloading a new firmware version may also cause an extra step to be performed after the
firmware download. If this happens, the user will be given informational messages indicating
the additional steps. Although not necessary, it is recommended that all templates be backed-
up to the PC before a firmware update. If power is disconnected during a firmware update, the
Bioscrypt unit may become inoperable.