User's Manual

A PPENDIX A Q UALITY AND C ONTENT
82
© Copyright 2002, Bioscrypt Inc. All rights reserved.
Scanning an Image
When the unit properly reads a fingerprint, it looks for image quality and fingerprint
content. When a raw image is collected from the sensor, the Veri-Series unit searches
for the fingerprint core.
Content scores are based upon the amount of non-ambiguous data in the region
of the core. The higher the content, the greater the degree of useful information.
See Section A.3 for a thorough discussion of content
Quality scores are based on how well the ridge pattern is defined within the image.
For best image quality, be sure that the sensor window is clear of dirt, residue, or
other material that can block the BII_Units view of the fingerprint. See Section A.3
for a thorough discussion on quality.
Once the image is scanned, the BII_Unit then creates and stores the resulting
fingerprint template.
Storing User Templates on the Unit
The Veri-Series unit recognizes users by matching current images to stored
templates of previously enrolled fingerprints. Along with the fingerprint, the
VeriProx and VeriFlex require a proximity card with a unique user ID number.
The Veri-Series readers allow associating multiple fingerprints with a single
Template ID. Each instance of a template with a specific ID has a unique index (up
to 256 indices possible (0-255)). This allows a VeriProx and VeriFlex users to have
a single proximity card, but be able to enroll multiple fingers. During
VERIFICATION, a user waves their card at the VeriProx / VeriFlex reader and
places their finger on the sensor. The unit will then scan the current fingerprint and
compare it against all enrolled templates for that specific ID. If there are multiple
templates enrolled under one ID, then the VeriProx / VeriFlex will check templates
in the numerical order based on their index.
Example: On Card # 123, a person ENROLLs both their left and right index
fingers. The next time that user goes to verify, they wave Card #
123 and place a finger on the sensor. The VeriProx scans the
current finger and compares it against the first template (the right
index finger, Template ID 123 0). If a match is found, the
VERIFICATION is PASSED and the operation ends. If a match is
not found, the VeriProx will check the second print (the left index
finger, Template ID 123 1). If a match is found, the
VERIFICATION is PASSED and the operation ends. If the match