User's Manual

A PPENDIX C V-PASS T EMPLATE D IFFERENCES
92
© Copyright 2002, Bioscrypt Inc. All rights reserved.
For installations using a “Mixed” network where both V-PASS units and VeriFlex / VeriProx /V-
Smart units are used, Bioscrypt recommends the follow guidelines to help manage templates:
1. A PC-based enrollment stations using the VeriAdmin software should be used for
all template enrollments.
2. All enrollments should be done using a V-PASS and stored on the PC.
3. V-PASS templates can be converted to VeriProx / VeriFlex templates using the
VeriAdmin Software (see the Template Conversion section). After this process,
the Administrator will have both a V-PASS compatible template and a VeriProx /
VeriFlex compatible template for each user.
4. Use the Bioscrypt designated extensions of “.tem” for VeriFlex / VeriProx
templates and “.mtm” for V-PASS templates.
Example:
PC Enrollment station is setup with an attached V-PASS unit and running the
VeriAdmin Management software.
Using the Advanced Enrollment dialog, the Administrator will enter an ID (ex:
1122) and sample enroll 3 different fingers and chose the best one as indicated
by the software.
This fingerprint template will be save to the PC (ex: 1122_0.mtm).
The Administrator will use the Template Conversion utility to create a VeriFlex /
VeriProx template (ex: 1122_0.tem).
Template 1122_0.mtm will then be transferred to all V-PASS units.
Template 1122_0.tem will then be transferred to all VeriFlex / VeriProx / V-
Smart units.