U NIT P ARAMETER S ETTINGS
56
© Copyright 2002, Bioscrypt Inc. All rights reserved.
The string is numeric and ranges from 0 to 255.
If the box is unchecked the site code read from the proximity card will be passed
through in the Wiegand out string.
On Fail Send Inverse Parity
When you check the On Fail Send Inverse Parity box, a failed verify will result in
the Wiegand string being sent on the Wiegand out lines with inversed parity to
indicate the failure.
Enable INPUT
This option in the Wiegand Settings section will enable Wiegand INPUT when
checked and sent to the BII_UNIT. This allows all WIEGAND INPUT
communications. If this option is unchecked and sent to the BII_UNIT, all
WIEGAND INPUT data will be ignored.
Enable OUTPUT
This option in the Wiegand Settings section will enable Wiegand OUTPUT when
checked and sent to the BII_UNIT. This causes the WIEGAND OUTPUT string to
be sent whenever a WIEGAND INPUT is received (see PASS_THRU section
Wiegand Output related to Pass-Thru formats). If this option is unchecked and
sent to the BII_UNIT, all WIEGAND OUTPUT data will be ignored unless the
ALWAYS OUTPUT is selected.
ALWAYS OUTPUT
This option in the Wiegand Settings section will enable Wiegand OUTPUT on ALL
Verifications regardless of whether initiated by a Wiegand INPUT, a PC or any
other device
Pulse Width
Unchecking the USE DEFAULT option will allow the user to enter a custom Pulse
Width duration for Wiegand Output. This is NOT recommended unless the user is
very familiar with the device connected to the BII_Unit.
Pulse Interval
Unchecking the USE DEFAULT option will allow the user to enter a custom Pulse
Interval duration for Wiegand Output. This is NOT recommended unless the user
is very familiar with the device connected to the BII_Unit.
Wiegand PASS-THRU formats
When used with MV1100/MV1200 firmware version 2.50 or higher, the
VeriAdmin software allows expanded Wiegand compatibility by allowing definition