User's Manual

Veri-Series Setup Guide
© Copyright 2005 Bioscrypt Inc. All rights reserved. Document #430-00111-18
16
Configuring Readers
1. Set up a configuration station
a. Wire the unit for power:
V-Prox/V-Flex/V-Pass: Connect the RED pigtail wire to
9-24V DC power and the BLACK wire to power
ground.
V-Smart: Connect the RED pigtail wire to 9-12V DC
power and the BLACK wire to power ground.
V-Station: Connect 12.5-24V power in to the +(POS)
Weidmuller connector and the power ground to the –
(NEG) connector.
b. Optionally wire up Wiegand output to a door controller.
c. Have a computer running VeriAdmin software available.
d. Have RJ11 communications cable available.
2. Connect the reader for communication
a. Connect RJ11 to reader and DB9 to PC COM port.
b. Plug pigtail cable into reader (if not a V-Station) and
connect power to appropriate conductors identified in
the charts on pages 11 and 12.
Wiegand Ground
Wiegand Out Data1
Wiegand Out Data0
See Page 11 for Color Codes
Powe
r
Supply
+12 VDC
Ground
Pigtail OR
Doo
r
Controlle
r
Data 0
Data 1
Common
Earth
Ground
To
Com
p
ute
r
Weidmuller