User's Manual

Veri-Series Setup Guide
© Copyright 2005 Bioscrypt Inc. All rights reserved. Document #430-00111-18
23
Mounting Readers On The Wall
1. The readers come disassembled, however, if your reader has
previously been assembled then disassemble the reader body
and smart card module (for V-Smart only) from the wall plate.
a. On V-Smart remove security screw securing smart card
module
b. For products other than V-Station, remove security screw
securing the Aux. port cover, and remove the Aux. port
cover by twisting (see graphics on page 25).
c. Remove #4-40 screw securing reader body to wall plate.
d. Remove smart card module (on V-Smart only) and
reader body by sliding up and pulling away from the
wall plate.
e. Keep screws and Aux. port cover for re-assembling the
device.
2. Define a location. A good location will have these qualities:
a. Comfortable height for finger
placement
NOTE: If readers need to be
mounted above 54” or below 48”,
please contact Bioscrypt for
available accessories to properly
readjust the angle of the reader for
optimal finger placement. Mounting
a reader above or below the
recommended height will not be
ergonomic for the user and will not
promote good finger placement on the sensor.
b. ADA considerations
48” – 54”