User's Manual

Veri-Series Setup Guide
© Copyright 2005 Bioscrypt Inc. All rights reserved. Document #430-00111-18
24
c. Provide clearance above and below for access
d. The access hole in the wall for wiring should be less than
1 ½ inches wide so that wall plate will cover it. It should
be less than 1 ½ inches tall if mounting into dry wall so
that there is enough material to hold the anchor. The
recommended size is 1 inch wide by 1 1/8 inches tall to
match the opening in the wall plate.
e. For V-Smart, the access hole in the wall for wiring should
be less than 4 ½ inches wide so that wall plate will cover
it. It should be less than 2 ½ inches tall if mounting into
dry wall so that there is enough material to hold the
anchor. The recommended size is 3 ½ inches wide by 2
½ inches tall.
f. For V-Station, the rear of the unit will protrude past the
wall plate and into the wall approximately 1 inch
(depending on the Weidmuller connectors attached).
The access hole must be exactly the size of the hole in
the wall plate (136mm (~5 3/8”) wide by 69mm (~2 ¾”)
tall). It may be helpful to trace the edges of the hole in
the wall plate in pencil before cutting.
g. Please see pages 26 – 28 for templates for the single-
gang and double-gang mounting plates. These
templates are dimensioned in millimeters (mm).
3. Make pigtail (or Weidmuller for V-Station) wiring connections to
power, Wiegand or other connections prior to mounting wall
plate.
4. For the V-Smart, feed pigtail cable from Smart Card Module
through hole in wall plate from the front and connect to pigtail
cable already wired in wall cutout.
5. For the V-Smart, connect Smart Card Module to wall plate.
Line up four tabs, push forward and then down. Secure smart
card module with the security screw at the bottom.