User's Manual

V ERIFICATION A CTION R ESPONSE
78
© Copyright 2002, Bioscrypt Inc. All rights reserved.
Figure 42: Verification Action Response
Verification Action Response
Choosing the Verification Action Response menu item will allow users to
customize the way the unit responds to a Verification Action.
Under Normal operations, the Veri-Series unit will respond based on
how a Verification Action was initiated. When a Wiegand INPUT
initiates the action, a Wiegand OUTPUT is used to respond. When a
Verification Action is initiated over a communications port by using the
Bioscrypt DLL or low-level commands (described in the MV1100 SDK),
then the response packet is
returned on the same
communication port (either HOST or AUX). This
menu allows the user to select other Verification Responses in addition to the normal
response.
The Line Trigger is a signal line that will trigger for the defined number of seconds on a
successful verification. Although not a true TTL level signal, this trigger could be used to
initiate a relay or other device. The Line Trigger is the GREEN wire on the Veri-Series
pigtail.
It is recommended that only advanced users who are working with the SDK and writing
their own custom software attempt to enable the HOST or AUX ALWAYS operations.
Please call Bioscrypt Technical Support with any questions.
Figure 43: Verification Action Dialog