Selecting the Right Power Supply
Most power supplies in the market today provide good input/output isolation,
however those which do not provide isolation (or have hit leakage capacitance),
coupled with accidental AC power lines interchange, present serious ground fault
problems for installers. With ground fault, the signal reference between subsystems
may be 115 VAC apart. If these subsystems are interconnected, the large
potential difference will cause equipment damage or personal injury. We
recommend use of isolated power supplies only.
All factory supplied power supply assemblies are either switching or regulated
linear supplies and are isolated for safety and to minimize ground loop problems.
WARNINGWARNING
Use only a UL-Listed Class II power supply at 12V DC, 500mA.